EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Impact of intraoperative CT on implant accuracy and reoperation rates in orbital floor reconstruction

Anna Persson, Anders Arbrandt, Babak Alinasab, Nikoo Bazsefidpay, Ulf Höckerfelt, Anders Johansson, Eva Larsson, Konstantinos Roussos, Andreas Thor, Daniel Nowinski

Journal of Plastic Surgery and Hand Surgery · 03.08.2026 · 61 · 197-202

DOI: 10.2340/jphs.v61.46475 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Plastic Surgery and Hand Surgery, online erschienen am 03.08.2026. Verfasst von Anna Persson und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic and Maxillofacial Surgery, Uppsala University Hospital, Uppsala, Sweden; Department of Surgical Sciences, Plastic Surgery, Upps…. Hauptthemen laut MEDLINE: Reoperation, Orbital Fractures, Tomography, X-Ray Computed, Orbital Implants. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Implant malposition is a leading cause of reoperation after orbital floor reconstruction. Intraoperative computed tomography (CT) enables immediate assessment and correction, however its impact on implant positioning accuracy and outcomes remains insufficiently studied. Materials and Methods: This retrospective study included 86 patients with isolated orbital floor fractures treated with radiopaque implants between 2011 and 2023 at Uppsala University Hospital. Sixty-five patients underwent postoperative CT and 21 intraoperative CT. Eight senior surgeons from all Swedish university hospitals independently reviewed anonymized scans under hypothetical intraoperative and postoperative conditions, indicating whether they would adjust the implant intraoperatively or recommend reoperation postoperatively. In the intraoperative group, implant position was assessed on final CT obtained after any CT-guided adjustment. Actual re-intervention rates were recorded.

Results

Recommendations for implant adjustment were significantly more frequent in the postoperative CT group than in the intraoperative CT group (45% vs. 19%, p = 0.042). Unanimous agreement that no adjustment was required occurred more often in the intraoperative CT group (48% vs. 22%). Consensus among ≥3 experts favoring reoperation was observed in 20% of postoperative cases and in none of the intraoperative cases. The perceived need for reoperation was lower in the intraoperative than in the postoperative CT group (5% vs. 15%, p = 0.45), as were actual reoperation rates (5% vs. 11%, p = 0.68).

Conclusions

Intraoperative CT was associated with improved expert-assessed implant positioning. Although reoperation rates were lower in the intraoperative CT group, these differences did not reach statistical significance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ReoperationOrbital FracturesTomography, X-Ray ComputedOrbital ImplantsPlastic Surgery ProceduresHumansRetrospective StudiesFemaleMaleAdultMiddle AgedIntraoperative CareAdolescentAgedYoung Adult

Autor:innen und Institutionen

  • Department of Plastic and Maxillofacial Surgery, Uppsala University Hospital, Uppsala, Sweden; Department of Surgical Sciences, Plastic Surgery, Uppsala University, Uppsala, Sweden. anna.persson@uu.se.
  • Department of Otorhinolaryngology and Head and Neck Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden; The ENT Institute, Carlanderska Hospital, Gothenburg, Sweden.
  • Department of Clinical Sciences, Intervention and Technology, Division of Otorhinolaryngology, Karolinska Institutet, Karolinska University Hospital, Stockholm, Sweden.
  • Department of Oral & Maxillofacial Surgery, School of Medical Sciences, Faculty of Medicine and Health, Örebro University, Örebro, Sweden; Head-Neck and Plastic Surgery Clinic, Department of Oral and Maxillofacial Surge…
  • Department of Otorhinolaryngology and Head and Neck Surgery, Skåne University Hospital, Lund, Sweden.
  • Department of Clinical Science, Otorhinolaryngology, Umeå University, Umeå, Sweden.

Zitieren

APA

Persson, A., Arbrandt, A., Alinasab, B., Bazsefidpay, N., Höckerfelt, U., Johansson, A., Larsson, E., Roussos, K., Thor, A., & Nowinski, D. (2026). Impact of intraoperative CT on implant accuracy and reoperation rates in orbital floor reconstruction. Journal of Plastic Surgery and Hand Surgery, 61, 197-202. https://doi.org/10.2340/jphs.v61.46475

Vancouver

Persson A, Arbrandt A, Alinasab B, Bazsefidpay N, Höckerfelt U, Johansson A, et al. Impact of intraoperative CT on implant accuracy and reoperation rates in orbital floor reconstruction. Journal of Plastic Surgery and Hand Surgery. 2026;61:197-202. doi:10.2340/jphs.v61.46475

BibTeX
@article{Persson2026,
  author = {Persson, Anna and Arbrandt, Anders and Alinasab, Babak and Bazsefidpay, Nikoo and Höckerfelt, Ulf and Johansson, Anders and Larsson, Eva and Roussos, Konstantinos and Thor, Andreas and Nowinski, Daniel},
  title = {Impact of intraoperative CT on implant accuracy and reoperation rates in orbital floor reconstruction},
  journal = {Journal of Plastic Surgery and Hand Surgery},
  year = {2026},
  volume = {61},
  pages = {197--202},
  doi = {10.2340/jphs.v61.46475}
}
Kostenlos starten →