EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimizing localization accuracy in peroneal artery perforator sequential flap transplantation with digital subtraction angiography and high-frequency ultrasound

Yong-Pei Chen, Hai-Yan Zhong, Rui Yang, Ming-Li Zou, Qian Wang, Yong Chen, Min Wang, Si-Ming Yuan

Journal of Plastic Surgery and Hand Surgery · 2025

DOI: 10.2340/jphs.v60.42954 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Plastic Surgery and Hand Surgery, 2025. Verfasst von Yong-Pei Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic Surgery, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China. Hauptthemen laut MEDLINE: Perforator Flap, Angiography, Digital Subtraction. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The peroneal artery perforator flap is widely used to repair deep defects in the distal lower leg and ankle. However, the success of flap transplantation depends on the accurate location of the peroneal artery perforators, which can be a challenge due to potential vascular damage and anatomical variations. This study utilizes digital subtraction angiography and high-frequency ultrasound to clarify the anatomical features of the peroneal artery and its perforators and accurately locate these perforators, thereby improving preoperative design and clinical outcomes. Peroneal artery perforator sequential flaps were employed to repair the wounds and donor sites, with the second donor site sutured directly. A total of 36 peroneal artery perforators were identified in seven patients, with an average of 5.14 perforators per patient. The majority of these perforators (47.22%) were concentrated in the middle segment of the lower leg. All flaps underwent tension-free primary closure and survived successfully, presenting a smooth appearance, a fine texture, and a color similar to that of the surrounding skin. Only a linear scar was left in the secondary donor site, which did not affect the overall appearance of the limb. This technique can accurately localize peroneal artery perforators, optimize the design of peroneal artery perforator sequential flaps, and facilitate the success of the surgery and postoperative esthetic recovery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Perforator FlapAngiography, Digital SubtractionHumansMaleFemaleAdultMiddle AgedUltrasonographyPlastic Surgery ProceduresArteriesLeg

Autor:innen und Institutionen

  • Department of Plastic Surgery, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
  • Department of Ultrasound, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
  • Department of Plastic Surgery, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China; Department of Plastic Surgery, Jinling Hospital, The First School of Clinical Medicine…

Zitieren

APA

Chen, Y. P., Zhong, H. Y., Yang, R., Zou, M. L., Wang, Q., Chen, Y., Wang, M., & Yuan, S. M. (2025). Optimizing localization accuracy in peroneal artery perforator sequential flap transplantation with digital subtraction angiography and high-frequency ultrasound. Journal of Plastic Surgery and Hand Surgery. https://doi.org/10.2340/jphs.v60.42954

Vancouver

Chen YP, Zhong HY, Yang R, Zou ML, Wang Q, Chen Y, et al. Optimizing localization accuracy in peroneal artery perforator sequential flap transplantation with digital subtraction angiography and high-frequency ultrasound. Journal of Plastic Surgery and Hand Surgery. 2025. doi:10.2340/jphs.v60.42954

BibTeX
@article{Chen2025,
  author = {Chen, Yong-Pei and Zhong, Hai-Yan and Yang, Rui and Zou, Ming-Li and Wang, Qian and Chen, Yong and Wang, Min and Yuan, Si-Ming},
  title = {Optimizing localization accuracy in peroneal artery perforator sequential flap transplantation with digital subtraction angiography and high-frequency ultrasound},
  journal = {Journal of Plastic Surgery and Hand Surgery},
  year = {2025},
  doi = {10.2340/jphs.v60.42954}
}
Kostenlos starten →