EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of dentine moisture conditions on interfacial adaptation of a calcium silicate-based sealer compared with an epoxy resin-based sealer: an SEM/EDX analysis

Maha M Yahya, Baidaa Mohammed Zeidan, Njwan Fadhel Shehab

Biomaterial Investigations in Dentistry · 16.07.2026 · 13 · 583-592

DOI: 10.2340/biid.v13.46517 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomaterial Investigations in Dentistry, online erschienen am 16.07.2026. Verfasst von Maha M Yahya und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Conservative Dentistry, College of Dentistry, University of Mustansiriyah, Baghdad, Iraq. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

To evaluate the effect of dentine moisture conditions on interfacial adaptation of a calcium silicate-based sealer (Bio-C Sealer) compared with that of an epoxy resin–based sealer (AH Plus Jet) at different root levels.

Methods

Sixty extracted single-rooted teeth were prepared using ProTaper Universal system up to size F3 and randomly allocated to two groups (n = 30) according to the type of sealer. Each group was then further subdivided into three subgroups (n = 10 each) according to dentine moisture condition: dry (ethanol as final irrigant), normal moist (blotted dry), and wet (canals left flooded). Root sections (2 mm in thickness) were obtained at 3 mm (apical) and 8 mm (coronal). Interfacial adaptation was assessed using scanning electron microscopy (SEM) analysis, while elemental composition was analyzed utilizing energy-dispersive X-ray spectroscopy analysis (EDX). Data were analyzed using two-way analysis of variance and Tukey’s post hoc test (p ≤ 0.05).

Results

Dentine moisture significantly affected interfacial adaptation. AH Plus Jet demonstrated superior adaptation under dry conditions, while Bio-C Sealer demonstrated optimal adaptation under moist conditions. EDX analysis revealed significantly higher levels of calcium and phosphorus in the Bio-C Sealer compared with the AH Plus group (p ≤ 0.019; p ≤ 0.036). Within the Bio-C Sealer group, calcium levels were significantly lower coronally (p = 0.016) than apically. Silicon and carbon were higher in AH Plus (p < 0.01), while oxygen was higher in Bio-C (p < 0.001).

Conclusion

Dentine moisture conditions significantly influence the performance of sealer. AH Plus performs optimally under dry conditions, while Bio-C Sealer demonstrates superior performance in moist environments.

Schlagwörter

Stichwörter der Autor:innen

Adhesive interfaceEDX analysisdentine moistureinterfacial adaptationsealer

Autor:innen und Institutionen

  • Department of Conservative Dentistry, College of Dentistry, University of Mustansiriyah, Baghdad, Iraq.
  • Department of Conservative Dentistry, College of Dentistry, University of Mosul, Mosul, Iraq.

Zitieren

APA

Yahya, M. M., Zeidan, B. M., & Shehab, N. F. (2026). Effect of dentine moisture conditions on interfacial adaptation of a calcium silicate-based sealer compared with an epoxy resin-based sealer: an SEM/EDX analysis. Biomaterial Investigations in Dentistry, 13, 583-592. https://doi.org/10.2340/biid.v13.46517

Vancouver

Yahya MM, Zeidan BM, Shehab NF. Effect of dentine moisture conditions on interfacial adaptation of a calcium silicate-based sealer compared with an epoxy resin-based sealer: an SEM/EDX analysis. Biomaterial Investigations in Dentistry. 2026;13:583-592. doi:10.2340/biid.v13.46517

BibTeX
@article{Yahya2026,
  author = {Yahya, Maha M and Zeidan, Baidaa Mohammed and Shehab, Njwan Fadhel},
  title = {Effect of dentine moisture conditions on interfacial adaptation of a calcium silicate-based sealer compared with an epoxy resin-based sealer: an SEM/EDX analysis},
  journal = {Biomaterial Investigations in Dentistry},
  year = {2026},
  volume = {13},
  pages = {583--592},
  doi = {10.2340/biid.v13.46517}
}
Kostenlos starten →