Effect of salivary pH variations on the adhesive performance of Transbond XT and Orthocem in orthodontic bracket bonding
Biomaterial Investigations in Dentistry · 23.03.2026 · 13 · 141-146
DOI: 10.2340/biid.v13.45568 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomaterial Investigations in Dentistry, online erschienen am 23.03.2026. Verfasst von Lismory Karina Leiton Narváez und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, University of the Hemispheres, Quito, Ecuador. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
This in vitro study aimed to evaluate the shear bond strength of orthodontic brackets bonded to acrylic resin specimens with two adhesive systems, Transbond XT and Orthocem, under different salivary pH levels (4, 5, 6, and 7). Materials and methods: A total of 120 acrylic resin specimens (Brava Block®, FGM) were prepared and randomly assigned to three groups: control bonded with Transbond XT and Orthocem with no salivary exposure (n = 24), Transbond XT (n = 48), and Orthocem (n = 48). Each adhesive group was subdivided and immersed in artificial saliva at pH 4, 5, 6, or 7 for 30 days. Metal premolar brackets (Vector+ Roth prescription, Aditek®) were bonded following manufacturers’ protocols and subjected to shear bond strength testing using a Universal Testing Machine, following ISO 4049 standards. Data were analyzed with Analysis of Variance (ANOVA), t-test, and Tukey tests at a significance level of p < 0.05.
Results
Transbond XT consistently showed higher bond strength than Orthocem across all pH levels. Maximum resistance was observed at pH 7 (21.19 ± 5.06 MPa), followed by the control group (19.64 ± 5.28 MPa). Orthocem demonstrated significantly lower values, ranging from 9.51 ± 3.87 MPa (pH 5) to 4.94 ± 2.15 MPa (pH 6). Acidic conditions reduced the bond strength of both adhesives, but Transbond XT maintained clinically reliable values, while Orthocem was more susceptible to performance decline at moderately acidic levels.
Conclusions
Salivary pH directly influenced adhesive performance. Transbond XT demonstrated superior resistance under all conditions, whereas Orthocem showed lower but still clinically acceptable shear bond strength values, except at pH 6, where a marked decrease was observed.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthodontics, University of the Hemispheres, Quito, Ecuador.
- Department of Endodontics, University of the Hemispheres, Quito, Ecuador.
- Department of Orthodontics, Ingá University Center Uningá, Maringá, Brazil.
ORCID-Profile: Lismory Karina Leiton Narváez, Marjory Elizabeth Vaca Zapata, Mauricio Aguirre Balseca, Karina Maria Salvatore Freitas, Yalil Rodríguez
Zitieren
APA
Leiton Narváez, L. K., Vaca Zapata, M. E., Aguirre Balseca, M., Freitas, K. M. S., & Rodríguez, Y. (2026). Effect of salivary pH variations on the adhesive performance of Transbond XT and Orthocem in orthodontic bracket bonding. Biomaterial Investigations in Dentistry, 13, 141-146. https://doi.org/10.2340/biid.v13.45568
Vancouver
Leiton Narváez LK, Vaca Zapata ME, Aguirre Balseca M, Freitas KMS, Rodríguez Y. Effect of salivary pH variations on the adhesive performance of Transbond XT and Orthocem in orthodontic bracket bonding. Biomaterial Investigations in Dentistry. 2026;13:141-146. doi:10.2340/biid.v13.45568
BibTeX
@article{LeitonNarvez2026,
author = {Leiton Narváez, Lismory Karina and Vaca Zapata, Marjory Elizabeth and Aguirre Balseca, Mauricio and Freitas, Karina Maria Salvatore and Rodríguez, Yalil},
title = {Effect of salivary pH variations on the adhesive performance of Transbond XT and Orthocem in orthodontic bracket bonding},
journal = {Biomaterial Investigations in Dentistry},
year = {2026},
volume = {13},
pages = {141--146},
doi = {10.2340/biid.v13.45568}
}
EUVIMED