High revision rate of metal-backed glenoid component and impact on the overall revision rate of stemless total shoulder arthroplasty: a cohort study from the Danish Shoulder Arthroplasty Registry
Acta Orthopaedica · 2024
DOI: 10.2340/17453674.2024.41014 ↗Kurz gefasst
Kohortenstudie in der Zeitschrift Acta Orthopaedica, 2024. Verfasst von Marc R K Nyring und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Herlev and Gentofte Hospital, Hellerup. mkri0209@regionh.dk. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Reoperation, Registries, Prosthesis Design. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background and purpose: There is controversy regarding the results of stemmed and stemless total shoulder arthroplasty (TSA) used for osteoarthritis. Therefore, we aimed to compare revision rates of stemmed and stemless TSA and to examine the impact of metal-backed glenoid components.
Methods
We included all patients reported to the Danish Shoulder Arthroplasty Register from January 1, 2012 to December 31, 2022 with an anatomical TSA used for osteoarthritis. Primary outcome was revision (removal or exchange of components) for any reason.
Results
3,338 arthroplasties were included. The hazard ratio for revision of stemless TSA adjusted for age and sex was 1.83 (95% confidence interval [CI] 1.21–2.78) with stemmed TSA as reference. When excluding all arthroplasties with a metal-backed glenoid component, the adjusted hazard ratio for revision of stemless TSA was 1.37 (CI 0.85–2.20). For the Eclipse stemless TSA system, the adjusted hazard ratio for revision of a metal-backed glenoid component was 8.75 (CI 2.40–31.9) with stemless Eclipse with an all-polyethylene glenoid component as reference.
Conclusion
We showed that the risk of revision of stemless TSAs was increased and that it was related to their combination with metal-backed glenoid components.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, Hellerup. mkri0209@regionh.dk.
- Department of Orthopedic Surgery, Herlev and Gentofte Hospital, Hellerup.
- Department of Orthopedic Surgery, Aalborg University Hospital, Aalborg, Denmark.
Zitieren
APA
Nyring, M. R. K., Olsen, B. S., Jensen, S. L., & Rasmussen, J. V. (2024). High revision rate of metal-backed glenoid component and impact on the overall revision rate of stemless total shoulder arthroplasty: a cohort study from the Danish Shoulder Arthroplasty Registry. Acta Orthopaedica. https://doi.org/10.2340/17453674.2024.41014
Vancouver
Nyring MRK, Olsen BS, Jensen SL, Rasmussen JV. High revision rate of metal-backed glenoid component and impact on the overall revision rate of stemless total shoulder arthroplasty: a cohort study from the Danish Shoulder Arthroplasty Registry. Acta Orthopaedica. 2024. doi:10.2340/17453674.2024.41014
BibTeX
@article{Nyring2024,
author = {Nyring, Marc R K and Olsen, Bo S and Jensen, Steen L and Rasmussen, Jeppe V},
title = {High revision rate of metal-backed glenoid component and impact on the overall revision rate of stemless total shoulder arthroplasty: a cohort study from the Danish Shoulder Arthroplasty Registry},
journal = {Acta Orthopaedica},
year = {2024},
doi = {10.2340/17453674.2024.41014}
}
EUVIMED