EUVIMEDEUVIMED entdecken
Open Access

Frequency and Causes of Nocturnal Alarms in Youth and Young Adults With Type 1 Diabetes Using a First-Generation Hybrid Closed-Loop System

Erin C Cobry iD, Tim Vigers, Cari Berget, Laurel H Messer, R Paul Wadwa, Laura Pyle, Gregory P Forlenza

Diabetes Spectrum · 01.04.2024 · 37 (2) · 118-123

DOI: 10.2337/ds23-0003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diabetes Spectrum, online erschienen am 19.09.2023. Verfasst von Erin C Cobry und 6 weiteren Autor:innen. Beteiligte Einrichtung: University of Colorado Anschutz Medical Campus, Barbara Davis Center for Diabetes, Aurora, CO. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDDK NIH HHS, NIH.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Meeting glycemic recommendations is challenging for youth with type 1 diabetes. Diabetes technology, including continuous glucose monitoring (CGM) and hybrid closed-loop (HCL) automated insulin delivery systems, significantly increase achievement of glycemic targets; however, many youth struggle to sustain use of early HCL systems. Nocturnal alarm fatigue contributes to disrupted sleep and device discontinuation.

Methods

We examined the frequency and causes of nocturnal (10:00 p.m. to 6:00 a.m.) alarms in pediatric patients (N = 76, median age 14.5 years [interquartile range 11.8–17.0 years, range 7–24 years]) starting on a first-generation HCL system in a prospective observational study. Device data were analyzed with linear mixed-effects models to examine change across time at 3-month intervals for 12 months.

Results

At baseline (HCL system in nonautomated mode), participants averaged 3.3 ± 0.6 alarms per night. In the 2 weeks after starting HCL (automated) mode, alarm frequency significantly increased to 5.4 ± 0.5 times per night (P <0.001). Alarm frequency decreased through the remainder of the observational period; however, CGM sensor and HCL system use also declined. The types of alarms were evenly distributed among sensor maintenance, sensor threshold, pump, and HCL-specific alarms.

Conclusion

These data show that HCL system nocturnal alarms are frequent and may be barriers to sleep quality and device use. Further research is needed to assess the impact of diabetes technology on sleep and to determine method to improve sleep quality with technology use.

Autor:innen und Institutionen

  • University of Colorado Anschutz Medical Campus, Barbara Davis Center for Diabetes, Aurora, CO.
  • Colorado School of Public Health, Department of Biostatistics and Informatics, Aurora, CO.

ORCID-Profile: Erin C Cobry

Förderung

  • NIDDK NIH HHS
  • NIH

Zitieren

APA

Cobry, E. C., Vigers, T., Berget, C., Messer, L. H., Wadwa, R. P., Pyle, L., & Forlenza, G. P. (2024). Frequency and Causes of Nocturnal Alarms in Youth and Young Adults With Type 1 Diabetes Using a First-Generation Hybrid Closed-Loop System. Diabetes Spectrum, 37(2), 118-123. https://doi.org/10.2337/ds23-0003

Vancouver

Cobry EC, Vigers T, Berget C, Messer LH, Wadwa RP, Pyle L, et al. Frequency and Causes of Nocturnal Alarms in Youth and Young Adults With Type 1 Diabetes Using a First-Generation Hybrid Closed-Loop System. Diabetes Spectrum. 2024;37(2):118-123. doi:10.2337/ds23-0003

BibTeX
@article{Cobry2024,
  author = {Cobry, Erin C and Vigers, Tim and Berget, Cari and Messer, Laurel H and Wadwa, R Paul and Pyle, Laura and Forlenza, Gregory P},
  title = {Frequency and Causes of Nocturnal Alarms in Youth and Young Adults With Type 1 Diabetes Using a First-Generation Hybrid Closed-Loop System},
  journal = {Diabetes Spectrum},
  year = {2024},
  volume = {37},
  number = {2},
  pages = {118--123},
  doi = {10.2337/ds23-0003}
}
Kostenlos starten →