Advancing Continuous Glucose Monitoring for Inpatient Clinical Decision Support: Individual Algorithmic Mean Absolute Relative Difference
Diabetes Care · 01.01.2026 · 49 (1) · 99-104
DOI: 10.2337/dc25-1494 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diabetes Care, online erschienen am 03.11.2025. Verfasst von Jill von Conta und 6 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Artificial Intelligence in Medicine, University Hospital Essen, University Duisburg-Essen, Essen, Germany. Hauptthemen laut MEDLINE: Algorithms, Blood Glucose, Blood Glucose Self-Monitoring, Decision Support Systems, Clinical. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE Continuous glucose monitoring (CGM) is widely used to monitor glucose levels in patients with diabetes and guide insulin dosing in outpatients. In inpatient care, special regulatory requirements necessitate CGM accuracy as a prerequisite for its integration into clinical decision support. RESEARCH DESIGN AND METHODS To meet the specific demands of in-hospital care, CGM accuracy was retrospectively evaluated in 226 patients using paired CGM and point-of-care glucose measurements, assessed via mean absolute relative difference (MARD), Clarke Error Grid (CEG) analysis, and a modified version of the U.S. Food and Drug Administration agreement rule. A dynamic, patient-specific algorithm incorporating time lag correction and linear modeling was developed to minimize MARD and applied in a second cohort of 24 patients within the clinical workflow. RESULTS Data analysis showed an initial MARD of 10.30%, with 99.02% of data points located in zones A and B of the CEG. The application of the patient-specific optimization algorithm improved the MARD by 4.33%. Evaluation of the patient-specific algorithm on the second inpatient cohort demonstrated a 5.58% reduction in intrapersonal MARD, indicating its potential applicability within clinical workflows. CONCLUSIONS Patient-specific algorithmic refinements of CGM data demonstrate the potential to adequately address the unique demands of inpatient diabetes care by reducing intrapersonal MARD, paving the way for the adoption of CGM systems into hospital environments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Institute for Artificial Intelligence in Medicine, University Hospital Essen, University Duisburg-Essen, Essen, Germany.
- Science Consulting in Diabetes, Düsseldorf, Germany.
- Department of Endocrinology, Diabetes and Metabolism, University Hospital Essen, University Duisburg-Essen, Essen, Germany.
- Department of Diabetes and Endocrinology, Heart and Diabetes Center NRW, University Hospital, Ruhr University Bochum, Bad Oeynhausen, Germany.
ORCID-Profile: Jill von Conta
Zitieren
APA
von Conta, J., Bahnsen, F. H., Heinemann, L., van Baal, L., Kleesiek, J., Führer-Sakel, D., & Tan, S. (2026). Advancing Continuous Glucose Monitoring for Inpatient Clinical Decision Support: Individual Algorithmic Mean Absolute Relative Difference. Diabetes Care, 49(1), 99-104. https://doi.org/10.2337/dc25-1494
Vancouver
von Conta J, Bahnsen FH, Heinemann L, van Baal L, Kleesiek J, Führer-Sakel D, et al. Advancing Continuous Glucose Monitoring for Inpatient Clinical Decision Support: Individual Algorithmic Mean Absolute Relative Difference. Diabetes Care. 2026;49(1):99-104. doi:10.2337/dc25-1494
BibTeX
@article{vonConta2026,
author = {von Conta, Jill and Bahnsen, Fin H and Heinemann, Lutz and van Baal, Lukas and Kleesiek, Jens and Führer-Sakel, Dagmar and Tan, Susanne},
title = {Advancing Continuous Glucose Monitoring for Inpatient Clinical Decision Support: Individual Algorithmic Mean Absolute Relative Difference},
journal = {Diabetes Care},
year = {2026},
volume = {49},
number = {1},
pages = {99--104},
doi = {10.2337/dc25-1494}
}
EUVIMED