EUVIMEDEUVIMED entdecken
Open Access

Real-world Accuracy of CGM in Inpatient Critical and Noncritical Care Settings at a Safety-Net Hospital

Erin Finn, Lindsay Schlichting, Laura Grau, Ivor S Douglas, Rocio I Pereira iD

Diabetes Care · 01.10.2023 · 46 (10) · 1825-1830

DOI: 10.2337/dc23-0089 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diabetes Care, online erschienen am 10.08.2023. Verfasst von Erin Finn und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Endocrinology, Metabolism, and Diabetes, Department of Medicine, University of Colorado, Aurora, CO. Hauptthemen laut MEDLINE: Blood Glucose Self-Monitoring, Blood Glucose. Die Arbeit wurde bisher 48-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDDK NIH HHS, NIH, Robert Wood Johnson Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE We sought to determine real-world accuracy of inpatient continuous glucose monitoring (CGM) at multiple levels of acuity in a large safety-net hospital. RESEARCH DESIGN AND METHODS We analyzed records from hospitalized patients on Dexcom G6 CGM, including clinical, point of care (POC), and laboratory (Lab) glucose, and CGM data. POC/Lab values were matched to the closest timed CGM value. Encounters were divided into not critically ill (NCI) versus critically ill (CI). CGM accuracy was evaluated. RESULTS Paired readings (2,744 POC-CGM; 3,705 Lab-CGM) were analyzed for 233 patients with 239 encounters (83 NCI, 156 CI). POC-CGM aggregated and average mean absolute relative differences (MARD) were 15.1% and 17.1%. Lab-CGM aggregated and average MARDs were 11.4% and 12.2%. Accuracy for POC-CGM and Lab-CGM was 96.5% and 99.1% in Clarke Error Grid zones A/B. CONCLUSIONS Real-world accuracy of inpatient CGM is acceptable for NCI and CI patients. Further exploration of conditions associated with lower CGM accuracy in real-world settings is warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Glucose Self-MonitoringBlood GlucoseHumansInpatientsSafety-net ProvidersReproducibility of ResultsCritical Illness

Substanzen

Blood Glucose

Autor:innen und Institutionen

  • Division of Endocrinology, Metabolism, and Diabetes, Department of Medicine, University of Colorado, Aurora, CO.
  • Medicine Service, Denver Health and Hospital Authority, Denver, CO.
  • Department of Biostatistics and Informatics, Colorado School of Public Health, University of Colorado, Aurora, CO.
  • Department of Medicine, Pulmonary Science, and Critical Care Medicine, University of Colorado, Aurora, CO.

ORCID-Profile: Rocio I Pereira

Förderung

  • NIDDK NIH HHS
  • NIH
  • Robert Wood Johnson Foundation
  • Colorado School of Public Health Center for Innovative Design and Analysis (CIDA) and the University of Colorado School of Medicine Division of Endocrinology,…

Zitieren

APA

Finn, E., Schlichting, L., Grau, L., Douglas, I. S., & Pereira, R. I. (2023). Real-world Accuracy of CGM in Inpatient Critical and Noncritical Care Settings at a Safety-Net Hospital. Diabetes Care, 46(10), 1825-1830. https://doi.org/10.2337/dc23-0089

Vancouver

Finn E, Schlichting L, Grau L, Douglas IS, Pereira RI. Real-world Accuracy of CGM in Inpatient Critical and Noncritical Care Settings at a Safety-Net Hospital. Diabetes Care. 2023;46(10):1825-1830. doi:10.2337/dc23-0089

BibTeX
@article{Finn2023,
  author = {Finn, Erin and Schlichting, Lindsay and Grau, Laura and Douglas, Ivor S and Pereira, Rocio I},
  title = {Real-world Accuracy of CGM in Inpatient Critical and Noncritical Care Settings at a Safety-Net Hospital},
  journal = {Diabetes Care},
  year = {2023},
  volume = {46},
  number = {10},
  pages = {1825--1830},
  doi = {10.2337/dc23-0089}
}
Kostenlos starten →