2894-LB: Assessing Long-Term Glycemic Control Using Continuous Glucose Monitoring Data with a Machine Learning Algorithm
Diabetes · 05.06.2026 · 75 (Supplement_1)
DOI: 10.2337/db26-2894-lb ↗Kurz gefasst
Fachartikel in der Zeitschrift Diabetes, erschienen am 05.06.2026. Verfasst von JUEN GUO und 1 weiteren Autor:innen.
Abstract (Originalsprache)
Introduction and Objective: Poor long-term glycemic control increases the risk of complications such as cognitive decline and cardiovascular disease. Continuous glucose monitoring (CGM) enables the assessment of glycemic control by providing time-stamped glucose data. However, significant, rapid rises or dips in blood sugar can occur independent of eating because of metabolic, hormonal, and environmental factors, decreasing the accuracy of deciphering meal times over extended periods under free-living conditions.
Methods
We developed a machine-learning algorithm—a Bidirectional Long Short-Term Memory network with an Autocorrelation Function—that accurately identifies meal events directly from CGM data (Dexcom G4 Platinum). The algorithm was trained and cross-validated on CGM data collected from 39 inpatient participants during inpatient ad libitum feeding trials (range 45%-75% kcal CHO). In total, the meal times of 1,548 meals were recorded by research nurses at the NIH Clinical Center.
Results
Overall, the algorithm correctly identified 98.7% of meal events. Among the identified meals, 83% were detected within 10 minutes of the recorded meal time, 90% within 15 minutes, and 95% within 25 minutes. The 2-hour glucose AUCs of the predicted and actual postprandial glucose responses were highly correlated (r = 0.986 and 0.861 for absolute and incremental AUCs, respectively; p < 0.0001). For predicted absolute AUCs, Bland-Altman analysis revealed no significant linear bias (−0.01 ± 0.009 mg/dL, p = 0.37) and a trivial mean bias (−0.3 ± 0.14 mg/dL, p = 0.037), with an RMSE of 2.78 mg/dL. Similarly, for predicted incremental AUCs, no significant linear bias (−0.02 ± 0.028 mg/dL, p = 0.41) or mean bias (−0.49 ± 0.42 mg/dL, p = 0.24) was observed, with an RMSE of 8.21 mg/dL.
Conclusion
This algorithm can be used to assess dietary compliance in outpatient studies and to evaluate long-term glycemic control in patients consuming diets of 45-75% energy from carbohydrates under free-living conditions. Disclosure J. Guo: None. V. Darcey: None.
Zitieren
APA
GUO, J., & DARCEY, V. (2026). 2894-LB: Assessing Long-Term Glycemic Control Using Continuous Glucose Monitoring Data with a Machine Learning Algorithm. Diabetes, 75(Supplement_1). https://doi.org/10.2337/db26-2894-lb
Vancouver
GUO J, DARCEY V. 2894-LB: Assessing Long-Term Glycemic Control Using Continuous Glucose Monitoring Data with a Machine Learning Algorithm. Diabetes. 2026;75(Supplement_1). doi:10.2337/db26-2894-lb
BibTeX
@article{GUO2026,
author = {GUO, JUEN and DARCEY, VALERIE},
title = {2894-LB: Assessing Long-Term Glycemic Control Using Continuous Glucose Monitoring Data with a Machine Learning Algorithm},
journal = {Diabetes},
year = {2026},
volume = {75},
number = {Supplement_1},
doi = {10.2337/db26-2894-lb}
}
EUVIMED