1926-P: Association between Continuous Glucose Monitoring Alert Settings and Glycemic Outcomes

YAGUANG ZHENG, STEPHEN JOHNSON, EDUARDO ITURRATE, BEI WU, HENG HUANG, WILLIAM SMALL, SUSAN ZWEIG, ROZALINA MCCOY

Diabetes · 05.06.2026 · 75 (Supplement_1)

DOI: 10.2337/db26-1926-p ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diabetes, erschienen am 05.06.2026. Verfasst von YAGUANG ZHENG und 7 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction and Objective: Real-time continuous glucose monitoring (rtCGM) offers discretionary and customizable alert features that may improve the safety and effectiveness of glucose management; however, evidence on the impact of using the available alerts in real-world practice remains scarce. We aimed to examine whether utilization of different rtCGM alerts was associated with improved glycemic management among individuals with diabetes under routine care conditions.

Methods

This is a retrospective cohort study utilizing CGM data from electronic health records of a large U.S. academic health system. We included all Dexcom G6 users between 2020-2022 with sensor usage time ≥70% for each analyzed report.

Results

We identified 2,387 patients for analysis. Mean (±SD) age was 42.7±21.1 years, 51.4% were women, and 71.7% were white. Low alert on was associated with lower % time below range (TBR) 54-70 mg/dL (1.65±0.05 vs. 2.09±0.14; p=.02), %TBR <54 mg/dL (0.45±0.11 vs. 0.75±0.07; p=.007), and standard deviation (SD) (55.78±0.41 vs. 57.98±0.78; p=.004), but higher % time above range (TAR) 180-250 mg/dL (26.60±0.23 vs. 24.60±0.52; p= <.001). High alert on was associated with lower average glucose (172.70±0.81 vs. 182.43±1.42; p<.001), glucose management indicator (GMI) (7.40±0.02 vs. 7.64±0.04; p<.001), SD (55.33±0.42 vs. 59.01±0.54; p<.001), %TAR >250 (13.53±0.29 vs. 17.18±0.62; p<.001), %TAR 180-250 (26.20±0.24 vs. 27.69±0.36; <.001), higher % TIR (58.14±0.44 vs. 53.30±0.71; p<.001) and higher %TBR 54-70 (1.72±0.05 vs. 1.51±0.07; p=.01), but not with %TBR <54 (0.47±0.12 vs. 0.51±0.05; p=.71).

Conclusion

Enabling CGM high- or low-alert settings is associated with improved glycemia. Future applications of rtCGM should encourage activating high- and low-alert settings to optimize clinical benefit. Disclosure Y. Zheng: None. S. Johnson: None. E. Iturrate: None. B. Wu: None. H. Huang: None. W. Small: None. S. Zweig: None. R. McCoy: None. Funding New York Regional Center for Diabetes Translation Research (NY-CDTR) Pilot and Feasibility (P&F) Program Funding (P30DK111022-08).

Zitieren

APA

ZHENG, Y., JOHNSON, S., ITURRATE, E., WU, B., HUANG, H., SMALL, W., ZWEIG, S., & MCCOY, R. (2026). 1926-P: Association between Continuous Glucose Monitoring Alert Settings and Glycemic Outcomes. Diabetes, 75(Supplement_1). https://doi.org/10.2337/db26-1926-p

Vancouver

ZHENG Y, JOHNSON S, ITURRATE E, WU B, HUANG H, SMALL W, et al. 1926-P: Association between Continuous Glucose Monitoring Alert Settings and Glycemic Outcomes. Diabetes. 2026;75(Supplement_1). doi:10.2337/db26-1926-p

BibTeX
@article{ZHENG2026,
  author = {ZHENG, YAGUANG and JOHNSON, STEPHEN and ITURRATE, EDUARDO and WU, BEI and HUANG, HENG and SMALL, WILLIAM and ZWEIG, SUSAN and MCCOY, ROZALINA},
  title = {1926-P: Association between Continuous Glucose Monitoring Alert Settings and Glycemic Outcomes},
  journal = {Diabetes},
  year = {2026},
  volume = {75},
  number = {Supplement_1},
  doi = {10.2337/db26-1926-p}
}
Kostenlos starten →