Micro-CT determination of the porosity of two tricalcium silicate sealers applied using three obturation techniques
Journal of Oral Science · 2024
DOI: 10.2334/josnusd.24-0031 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Oral Science, 2024. Verfasst von Jinah Kim und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Dental Medicine, University of New England. Hauptthemen laut MEDLINE: Silicates, Root Canal Obturation, X-Ray Microtomography, Root Canal Filling Materials. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: NuSmile/Avalon Biomed, the University of New England College of Dental Medicine, University of North Carolina at Chapel Hill Adams School of Dentistry.
Abstract (Originalsprache)
PURPOSE: Using X-ray micro-computed tomography (micro-CT), the aim of this study was to measure the porosity of two tricalcium silicate sealers (EndoSequence BC and NeoSealer Flo) applied using three obturation techniques (single-cone, warm-vertical, and cold-lateral) to six single-rooted human teeth. METHODS: Six extracted, single-rooted human teeth were shaped with ProTaper Next rotary files and obturated with EndoSequence BC or NeoSealer Flo sealers and gutta-percha (GP) using one of the three techniques above. Micro-CT was used to map the full length of the canals. Deep learning cross-sectional segmentation was used to analyze image slices of the apical (0-2 mm) and coronal (14-16 mm from the apex) regions (n = 230-261 per tooth) for the areas of GP and sealer, as well as porosity. Median (%) with interquartile range of porosity were calculated , and the results were statistically analyzed with the Kruskal-Wallis test. RESULTS: In the apical region, EndoSequence BC had significantly fewer pores than NeoSealer Flo with the single-cone obturation (% median-interquartile range, IQR: 0.00-1.62) and warm-vertical condensation (5.57-10.32) techniques, whereas in the coronal region, NeoSealer Flo had significantly fewer pores than EndoSequence BC with these two techniques (0.39-5.02) and (0.10-0.19), respectively. There was no significant difference in porosity between the two sealers for the cold-lateral condensation technique in both the apical and coronal regions. CONCLUSION: For optimal obturation, the choice of technique and sealer is critical.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Dental Medicine, University of New England.
- Adams School of Dentistry, University of North Carolina at Chapel Hill.
- Rigaku America Corporation.
- Augusta University.
Förderung
- NuSmile/Avalon Biomed, the University of New England College of Dental Medicine
- University of North Carolina at Chapel Hill Adams School of Dentistry
Zitieren
APA
Kim, J., Vo, K., Dhaliwal, G. S., Takase, A., Primus, C., & Komabayashi, T. (2024). Micro-CT determination of the porosity of two tricalcium silicate sealers applied using three obturation techniques. Journal of Oral Science. https://doi.org/10.2334/josnusd.24-0031
Vancouver
Kim J, Vo K, Dhaliwal GS, Takase A, Primus C, Komabayashi T. Micro-CT determination of the porosity of two tricalcium silicate sealers applied using three obturation techniques. Journal of Oral Science. 2024. doi:10.2334/josnusd.24-0031
BibTeX
@article{Kim2024,
author = {Kim, Jinah and Vo, Kali and Dhaliwal, Gurmukh S and Takase, Aya and Primus, Carolyn and Komabayashi, Takashi},
title = {Micro-CT determination of the porosity of two tricalcium silicate sealers applied using three obturation techniques},
journal = {Journal of Oral Science},
year = {2024},
doi = {10.2334/josnusd.24-0031}
}
EUVIMED