Influence of head positioning errors on the accuracy of fully automated artificial intelligence-based cephalometric software

Alessandro Polizzi, Antonino Lo Giudice, Cristina Conforte, Gaetano Isola, Rosalia Leonardi

The Angle Orthodontist · 2025

DOI: 10.2319/123124-1075.1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Angle Orthodontist, 2025. Verfasst von Alessandro Polizzi und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Cephalometry, Artificial Intelligence, Software, Head. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate the accuracy of three fully automated software systems compared to nonautomated cephalometric analysis software tested using cephalograms featuring correct and incorrect head positions. Materials and Methods The study sample consisted of 40 lateral cephalograms retrieved retrospectively from a larger pool of pretreatment orthodontic records. Cephalograms were recruited and divided into correct head posture group (CHP) and incorrect head posture group (IHP). Cephalometric data were obtained by manual landmarking (Dolphin software), which served as a reference, and by fully automated AI software (WebCeph, Ceph Assistant, and AudaxCeph). Intraclass correlation coefficients (ICC) and paired t -tests were used for intragroup comparisons, whereas analysis of variance and post-hoc analysis were used to compare performance among artificial intelligence (AI) based software applications.

Results

The tested software exhibited a good level of consistency for angular measurements whereas linear measurements were more error-prone. AudaxCeph demonstrated the most consistent accuracy, achieving excellent agreement (ICC > 0.90) for several skeletal parameters; however, it failed in detecting soft tissue accurately. WebCeph and Ceph Assistant showed greater variability, especially for linear measurements (ICC < 0.50). Positional errors drastically reduced measurement accuracy, with linear parameters such as Go-Me showing the poorest agreement across all software.

Conclusions

AI-based cephalometric software demonstrated variable accuracy depending on the cephalometric measurement, and this pattern was exacerbated under conditions involving positional errors in cephalograms. Accordingly, oversight by expert clinicians is still required to minimize marginal error.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CephalometryArtificial IntelligenceSoftwareHeadHumansRetrospective StudiesReproducibility of ResultsMaleAnatomic LandmarksFemale

Stichwörter der Autor:innen

AudaxCephCeph AssistantCephalometric analysisDolphinFully automatic cephalometryOrthodonticsWebCeph

Zitieren

APA

Polizzi, A., Lo Giudice, A., Conforte, C., Isola, G., & Leonardi, R. (2025). Influence of head positioning errors on the accuracy of fully automated artificial intelligence-based cephalometric software. The Angle Orthodontist. https://doi.org/10.2319/123124-1075.1

Vancouver

Polizzi A, Lo Giudice A, Conforte C, Isola G, Leonardi R. Influence of head positioning errors on the accuracy of fully automated artificial intelligence-based cephalometric software. The Angle Orthodontist. 2025. doi:10.2319/123124-1075.1

BibTeX
@article{Polizzi2025,
  author = {Polizzi, Alessandro and Lo Giudice, Antonino and Conforte, Cristina and Isola, Gaetano and Leonardi, Rosalia},
  title = {Influence of head positioning errors on the accuracy of fully automated artificial intelligence-based cephalometric software},
  journal = {The Angle Orthodontist},
  year = {2025},
  doi = {10.2319/123124-1075.1}
}
Kostenlos starten →