Randomisierte kontrollierte Studie in der Zeitschrift The Angle Orthodontist, 2025-09. Verfasst von Zeyao Miao und 7 weiteren Autor:innen. Hauptthemen laut MEDLINE: Tooth Movement Techniques, Vibration, Low-Level Light Therapy. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate the influence of personalized aligner replacement, with or without physical methods of acceleration using low-frequency vibration combined with a low-level laser, on the tooth movement rate and accuracy of clear aligners. Materials and Methods Forty participants were randomly allocated to three groups. Fourteen participants used the standard replacement protocol in Group A, Group B included 14 participants using a personalized replacement protocol, and 12 participants in Group C followed the personalized replacement protocol and used a physical device that combined low-frequency vibration and low-level laser. Aligner replacement cycles of the first 12 steps were recorded, and GOM inspect suite software 2022 (GOM; Braunschweig, Germany) was used to evaluate maxillary molar movement accuracy using digital models collected before treatment and at the end of the 12th step.

Results

No significant difference was found in the accuracy of maxillary molar movement between Groups A and B, but the tooth movement rate in Group B was significantly greater. The accuracy of maxillary molar movement was similar in Groups B and C, and the tooth movement rate in Group C was significantly increased.

Conclusions

The personalized replacement protocol decreased the number of aligner replacement cycles without impacting the accuracy of tooth movement. With personalized replacement, a physical method of acceleration combining low-level laser and low-frequency vibration significantly accelerated orthodontic tooth movement and had little influence on the accuracy of tooth movement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tooth Movement TechniquesVibrationLow-Level Light TherapyHumansMaleFemaleAdolescentAdultMolarYoung AdultOrthodontic Appliance Design

Stichwörter der Autor:innen

Accelerating orthodontic tooth movementClear alignerLLLTLow-frequency vibrationPersonalized replacement protocol

Zitieren

APA

Miao, Z., Ren, L., Zhang, H., Zheng, C., Yang, Y., Zhu, J., Han, Y., & Wang, S. (2025). Influence of personalized replacement protocol and low-level laser therapy combined with vibration on tooth movement rate and tooth movement accuracy in clear aligner treatment: a randomized clinical trial. The Angle Orthodontist, 95(5), 530-537. https://doi.org/10.2319/100424-813.1

Vancouver

Miao Z, Ren L, Zhang H, Zheng C, Yang Y, Zhu J, et al. Influence of personalized replacement protocol and low-level laser therapy combined with vibration on tooth movement rate and tooth movement accuracy in clear aligner treatment: a randomized clinical trial. The Angle Orthodontist. 2025;95(5):530-537. doi:10.2319/100424-813.1

BibTeX
@article{Miao2025,
  author = {Miao, Zeyao and Ren, Liling and Zhang, Haijuan and Zheng, Chengdong and Yang, Yuxuan and Zhu, Jinyuan and Han, Yandong and Wang, Shuang},
  title = {Influence of personalized replacement protocol and low-level laser therapy combined with vibration on tooth movement rate and tooth movement accuracy in clear aligner treatment: a randomized clinical trial},
  journal = {The Angle Orthodontist},
  year = {2025},
  volume = {95},
  number = {5},
  pages = {530--537},
  doi = {10.2319/100424-813.1}
}
Kostenlos starten →