EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

Comparison of conventional and self-adhesive orthodontic bonding systems in white spot lesion formation: an in vitro confocal Raman microscopy analysis

Marwan El Helou, Manon Albaret, Emmanuel Nicolas, François Boutin, Richard Younes, Frederic Cuisinier, Stéphane Barthélemi

The Angle Orthodontist · 2026-07 · 96 (4) · 444-451

DOI: 10.2319/062725-527.1 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Angle Orthodontist, 2026-07. Verfasst von Marwan El Helou und 6 weiteren Autor:innen. Hauptthemen laut MEDLINE: Dental Enamel, Resin Cements, Dental Bonding, Orthodontic Brackets. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To compare the susceptibility of enamel to white spot lesion formation following the application of two orthodontic bonding protocols: a conventional three-step adhesive system and a two-step self-adhesive system with primer integrated into the resin. Materials and Methods Thirty extracted premolars were randomly allocated to two groups: Transbond XT (three-step system) and GC Ortho Connect (two-step self-adhesive system). After 7-day pH cycling, demineralization was assessed using Witec a300R confocal Raman microscopy. Phosphate intensity at 960 cm −1 was measured along a 130-µm enamel profile and normalized.

Results

Measurements by two operators showed high intraoperator and interoperator reliability (intraclass correlation coefficient = 0.82–0.92). GC samples exhibited a continuous decline in phosphate intensity, indicating extensive demineralization, while XT samples showed a midenamel plateau, suggesting mineral preservation. Spline modeling confirmed significantly higher phosphate retention in the XT group at middepth ( P < .001), with both groups showing surface demineralization near 130 µm ( P = .005).

Conclusions

The three-step adhesive system (Transbond XT) showed greater resistance to subsurface enamel demineralization than the self-adhesive system (GC Ortho Connect). These results suggest that using a separate primer may better protect enamel beyond the immediate bracket interface.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental EnamelResin CementsDental BondingOrthodontic BracketsHumansMicroscopy, ConfocalTooth DemineralizationSpectrum Analysis, RamanIn Vitro TechniquesBicuspid

Stichwörter der Autor:innen

Adhesive systemsEnamel demineralizationIn vitro studyOrthodontic bondingRaman microscopyWhite spot lesions

Substanzen

Transbond XTResin Cements

Zitieren

APA

El Helou, M., Albaret, M., Nicolas, E., Boutin, F., Younes, R., Cuisinier, F., & Barthélemi, S. (2026). Comparison of conventional and self-adhesive orthodontic bonding systems in white spot lesion formation: an in vitro confocal Raman microscopy analysis. The Angle Orthodontist, 96(4), 444-451. https://doi.org/10.2319/062725-527.1

Vancouver

El Helou M, Albaret M, Nicolas E, Boutin F, Younes R, Cuisinier F, et al. Comparison of conventional and self-adhesive orthodontic bonding systems in white spot lesion formation: an in vitro confocal Raman microscopy analysis. The Angle Orthodontist. 2026;96(4):444-451. doi:10.2319/062725-527.1

BibTeX
@article{ElHelou2026,
  author = {El Helou, Marwan and Albaret, Manon and Nicolas, Emmanuel and Boutin, François and Younes, Richard and Cuisinier, Frederic and Barthélemi, Stéphane},
  title = {Comparison of conventional and self-adhesive orthodontic bonding systems in white spot lesion formation: an in vitro confocal Raman microscopy analysis},
  journal = {The Angle Orthodontist},
  year = {2026},
  volume = {96},
  number = {4},
  pages = {444--451},
  doi = {10.2319/062725-527.1}
}
Kostenlos starten →