EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudieOpen Access

Comparison between effects of reverse curve of Spee nickel titanium archwire and stainless steel archwires with and without torque on the lower incisors in deep overbite treatment: a randomized control study

Farah Shakhtour, Kazem Al-Nimri

The Angle Orthodontist · 2025

DOI: 10.2319/051524-376.1 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift The Angle Orthodontist, 2025. Verfasst von Farah Shakhtour und 1 weiteren Autor:innen. Hauptthemen laut MEDLINE: Orthodontic Wires, Stainless Steel, Incisor, Torque. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To compare the effect between three different reverse curve of Spee (RCOS) archwires: 0.016 × 0.022-inch Nickel-Titanium and 0.019 × 0.025-inch stainless steel (SS) with and without crown labial torque (CLT) on lower incisors during deep overbite treatment. Materials and Methods Eighty subjects with deep overbite were randomly divided into three groups: the first group (mean age: 20.5 years) received SS RCOS with CLT, the second group (mean age: 19.4 years) was treated with 0.019 × 0.025-inch SS RCOS with zero CLT, the third group (mean age: 18.2 years) was treated with rocking-chair nickel-titanium (NiTi) 0.016 × 0.022-inch with RCOS. Two lateral cephalometric images were taken for each patient, one after alignment and the second after deep bite correction. These images were superimposed using the corpus axis to study the lower incisor horizontal and vertical changes.

Results

The lower incisor angular change was significantly smaller in Group II (−0.3°) compared to Group I (4.8°) and Group III (6.0°, P ≤ .001). Lower incisor anterior movement was reduced in Group II compared to Group I ( P = .014) and Group III ( P = .008). Group III showed significantly more downward movement of the lower Incisors ( P ≤ .001). The three groups showed comparable amounts of true intrusion (1 mm, P = .536).

Conclusions

0.016 × 0.022-inch NiTi and 0.019 × 0.025-inch SS with crown labial torque RCOS archwires resulted in similar proclination and forward movement of the lower incisors. Removal of anterior crown labial torque from the 0.019 × 0.025-inch SS RCOS archwire prevents lower incisor proclination and forward movement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Orthodontic WiresStainless SteelIncisorTorqueTitaniumNickelOverbiteHumansMaleFemaleYoung AdultAdolescentCephalometryOrthodontic Appliance DesignTooth Movement TechniquesDental Alloys

Stichwörter der Autor:innen

Curve of SpeeDeep overbite treatmentLower incisor proclination

Substanzen

Stainless SteelTitaniumNickeltitanium nickelideDental Alloys

Zitieren

APA

Shakhtour, F., & Al-Nimri, K. (2025). Comparison between effects of reverse curve of Spee nickel titanium archwire and stainless steel archwires with and without torque on the lower incisors in deep overbite treatment: a randomized control study. The Angle Orthodontist. https://doi.org/10.2319/051524-376.1

Vancouver

Shakhtour F, Al-Nimri K. Comparison between effects of reverse curve of Spee nickel titanium archwire and stainless steel archwires with and without torque on the lower incisors in deep overbite treatment: a randomized control study. The Angle Orthodontist. 2025. doi:10.2319/051524-376.1

BibTeX
@article{Shakhtour2025,
  author = {Shakhtour, Farah and Al-Nimri, Kazem},
  title = {Comparison between effects of reverse curve of Spee nickel titanium archwire and stainless steel archwires with and without torque on the lower incisors in deep overbite treatment: a randomized control study},
  journal = {The Angle Orthodontist},
  year = {2025},
  doi = {10.2319/051524-376.1}
}
Kostenlos starten →