Treatment outcomes, efficiency and complications of customized ceramic brackets compared with conventional fixed orthodontic appliances
The Angle Orthodontist · 11.09.2026
DOI: 10.2319/030326-188.1 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Angle Orthodontist, erschienen am 11.09.2026. Verfasst von Behnoosh Hormozi und 7 weiteren Autor:innen.
Abstract (Originalsprache)
Objectives
To compare treatment outcomes, efficiency, and bracket-related complications between customized ceramic brackets (LightForce) and conventional appliances. Materials and Methods This retrospective study included 75 patients treated in a private orthodontic practice (LightForce, n = 36; conventional, n = 39). Pretreatment malocclusion severity was assessed using the American Board of Orthodontics Discrepancy Index (ABO-DI). The primary outcome, treatment outcome quality, was assessed using the American Board of Orthodontics Objective Grading System (ABO-OGS). Secondary outcomes related to treatment efficiency and bracket-related complications were assessed by treatment duration, number of scheduled and emergency visits, and bracket failures. Between-group comparisons were conducted using Wilcoxon rank-sum tests for continuous variables and Fisher’s exact tests for categorical variables.
Results
Pretreatment ABO-DI scores were comparable between groups. Total posttreatment ABO-OGS scores were similar between the LightForce and conventional groups (29.0 vs 25.0; P = .061), although marginal ridge scores were higher in the LightForce group ( P < .001). LightForce treatment was completed in a shorter time (16.0 vs 19.0 months; P < .001) with fewer scheduled visits ( P = .012). However, the LightForce group experienced more bracket failures and more bracket related emergency visits (both P < .001). The presence of at least one bracket failure was higher in the LightForce group (80.6% vs 43.6%; P = .002).
Conclusions
Customized ceramic brackets (LightForce) achieved overall treatment quality comparable to conventional fixed appliances, but with improved treatment efficiency; however, they were associated with a higher rate of bracket-related complications.
Schlagwörter
Stichwörter der Autor:innen
Zitieren
APA
Hormozi, B., Fernandes Poleti, T., Romero, L., Montes, M. L., Chandhoke, T., Kuo, C. L., Zhong, K., & Uribe, F. (2026). Treatment outcomes, efficiency and complications of customized ceramic brackets compared with conventional fixed orthodontic appliances. The Angle Orthodontist. https://doi.org/10.2319/030326-188.1
Vancouver
Hormozi B, Fernandes Poleti T, Romero L, Montes ML, Chandhoke T, Kuo CL, et al. Treatment outcomes, efficiency and complications of customized ceramic brackets compared with conventional fixed orthodontic appliances. The Angle Orthodontist. 2026. doi:10.2319/030326-188.1