EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

Usefulness of an artificial intelligence–assisted indirect bonding method for optimizing orthodontic bracket positioning

Petra C Bachour, Robert T Klabunde, Thorsten Grünheid

The Angle Orthodontist · 2026-01 · 96 (1) · 93-99

DOI: 10.2319/022425-157.1 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Angle Orthodontist, 2026-01. Verfasst von Petra C Bachour und 2 weiteren Autor:innen. Hauptthemen laut MEDLINE: Orthodontic Brackets, Artificial Intelligence, Dental Bonding. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To compare the bracket positioning accuracy of a traditional and an artificial intelligence (AI)-assisted digital indirect bonding (IDB) method to explore the current usefulness of AI for optimizing orthodontic bracket positioning. Materials and Methods Twenty-five clinicians positioned brackets using traditional and AI-assisted digital IDB methods. Bracket positioning differences were quantified using digital superimposition of bracket setups and compared with an optimal setup. A total of 1800 bracket positioning differences were evaluated. One-tailed t -tests were used to determine whether these differences were within limits of 0.5 mm in mesial-distal and occlusal-gingival dimensions and within 2° for tip.

Results

Overall mean bracket position differences between the traditional and digital setups were 0.28 mm for mesial-distal placement and 0.32 mm for occlusal-gingival placement; both were significantly below the 0.5-mm limit. In contrast, differences in tip were 3.4°, which was significantly greater than the 2° limit. Comparisons with an optimal setup showed overall statistically significant differences in mean bracket positioning for tip but not for the mesial-distal or occlusal-gingival measurements for both the traditional and AI-assisted digital IDB methods. However, the digital method was more accurate for bracket tip.

Conclusions

Bracket positioning is consistent and highly accurate in linear dimensions with both traditional and digital IDB methods; however, AI may be useful for improving accuracy of bracket angulation. Clinicians who currently use traditional IDB methods may adopt AI-assisted digital IDB without compromising bracket positioning accuracy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Orthodontic BracketsArtificial IntelligenceDental BondingHumansOrthodontic Appliance Design

Stichwörter der Autor:innen

3D technologiesAccuracyArtificial intelligenceDigital workflowIndirect bonding

Zitieren

APA

Bachour, P. C., Klabunde, R. T., & Grünheid, T. (2026). Usefulness of an artificial intelligence–assisted indirect bonding method for optimizing orthodontic bracket positioning. The Angle Orthodontist, 96(1), 93-99. https://doi.org/10.2319/022425-157.1

Vancouver

Bachour PC, Klabunde RT, Grünheid T. Usefulness of an artificial intelligence–assisted indirect bonding method for optimizing orthodontic bracket positioning. The Angle Orthodontist. 2026;96(1):93-99. doi:10.2319/022425-157.1

BibTeX
@article{Bachour2026,
  author = {Bachour, Petra C and Klabunde, Robert T and Grünheid, Thorsten},
  title = {Usefulness of an artificial intelligence–assisted indirect bonding method for optimizing orthodontic bracket positioning},
  journal = {The Angle Orthodontist},
  year = {2026},
  volume = {96},
  number = {1},
  pages = {93--99},
  doi = {10.2319/022425-157.1}
}
Kostenlos starten →