EUVIMEDEUVIMED entdecken
Open Access

Effect of aging and mechanical brushing on color stability and translucency of three-dimensionally printed and thermoformed aligners of different thicknesses

Muhammet Fidan, Ibrahim Erhan Gelgor

The Angle Orthodontist · 2026-01 · 96 (1) · 83-92

DOI: 10.2319/011325-50.1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Angle Orthodontist, 2026-01. Verfasst von Muhammet Fidan und 1 weiteren Autor:innen. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Toothbrushing, Orthodontic Appliance Design. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The aim of this study was to evaluate the effect of aging and mechanical brushing on the color stability and translucency of three-dimensionally (3D) printed and thermoformed transparent aligners (clear aligners [CAs]) of different thicknesses. Materials and Methods Three types of CAs (Dentsply Sirona Essix [Group 1], Scheu-Dental Thermoforming Foils [Group 2], and 3D-printed Nexdent [Group 3]) in two thicknesses (0.75 mm and 1.0 mm) were used. Each group was divided into cleaned and noncleaned subgroups (n = 10). Samples were aged in artificial saliva and subjected to mechanical brushing. Color differences (ΔE 00 ) and relative translucency parameter values (RTP 00 ) were recorded at 1-week intervals over 4 weeks. Statistical analyses included generalized linear models and repeated measures analyses of variance (ANOVAs) for normally distributed parameters, and robust ANOVAs and Friedman tests for nonnormally distributed parameters ( P < .05).

Results

Group 1 had the highest mean RTP 00 values, while Group 3 had the lowest mean RTP 00 values. Noncleaned CAs exhibited higher RTP 00 values than cleaned CAs ( P < .05). RTP 00 values decreased significantly over time, with Group 3 showing notable differences between cleaned and noncleaned subgroups. Thinner materials (0.75 mm) displayed greater color changes than thicker ones (1 mm).

Conclusions

3D-printed CAs demonstrated more significant color variation and less translucency in comparison to thermoformed CAs. Regular cleaning helps maintain translucency and color stability, but the choice of aligner material is crucial.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalToothbrushingOrthodontic Appliance DesignColorHumansMaterials Testing

Stichwörter der Autor:innen

3D PrintingAlignerColor stabilityTranslucency parameter

Zitieren

APA

Fidan, M., & Gelgor, I. E. (2026). Effect of aging and mechanical brushing on color stability and translucency of three-dimensionally printed and thermoformed aligners of different thicknesses. The Angle Orthodontist, 96(1), 83-92. https://doi.org/10.2319/011325-50.1

Vancouver

Fidan M, Gelgor IE. Effect of aging and mechanical brushing on color stability and translucency of three-dimensionally printed and thermoformed aligners of different thicknesses. The Angle Orthodontist. 2026;96(1):83-92. doi:10.2319/011325-50.1

BibTeX
@article{Fidan2026,
  author = {Fidan, Muhammet and Gelgor, Ibrahim Erhan},
  title = {Effect of aging and mechanical brushing on color stability and translucency of three-dimensionally printed and thermoformed aligners of different thicknesses},
  journal = {The Angle Orthodontist},
  year = {2026},
  volume = {96},
  number = {1},
  pages = {83--92},
  doi = {10.2319/011325-50.1}
}
Kostenlos starten →