Quantitative evaluation of an artificial intelligence–driven remote monitoring system for occlusion assessment using patient-captured images
The Angle Orthodontist · 2026-11 · 96 (6) · 659-666
DOI: 10.2319/010926-30.1 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Angle Orthodontist, 2026-11. Verfasst von Daniel Bills und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objectives
To evaluate the accuracy of an artificial intelligence (AI) model developed by DentalMonitoring for assessing occlusal parameters from patient-acquired intraoral images, using intraoral scanner (IOS)–derived three-dimensional (3D)measurements as the reference standard. Materials and Methods This multicenter prospective study included 430 orthodontic patients from three clinics in the United States. Each participant completed a DentalMonitoring scan using the DM ScanBox and a clinician-acquired IOS scan. Midline deviation, overbite, overjet, and canine class were measured on IOS-generated 3D models using metrology-grade software (ZEISS Inspect). Three independent, blinded technicians performed measurements, with the median value used as the reference. Agreement between AI-generated and reference measurements was assessed using Passing-Bablok regression and relative bias analyses at predefined clinical thresholds.
Results
All occlusal parameters demonstrated agreement within clinically acceptable limits. Midline deviation and overbite showed the highest concordance, with intercepts near 0.00 mm, relative biases below 3%, and mean biases of −0.01 ± 0.26 mm and −0.04 ± 0.39 mm, respectively. Overjet was modestly overestimated (mean bias = +0.29 ± 0.52 mm), while canine class showed increasing underestimation at higher values (mean bias = −0.31 ± 0.91 mm).
Conclusions
The evaluated AI model demonstrated high agreement with IOS-based 3D measurements for midline deviation and overbite, with greater variability for overjet and canine classification. These results support the use of AI-assisted monitoring for screening and follow-up, while highlighting the need for further validation prior to routine clinical implementation.
Schlagwörter
Stichwörter der Autor:innen
Zitieren
APA
Bills, D., Benton, B., Dabney, W., & Sellke, T. A. (2026). Quantitative evaluation of an artificial intelligence–driven remote monitoring system for occlusion assessment using patient-captured images. The Angle Orthodontist, 96(6), 659-666. https://doi.org/10.2319/010926-30.1
Vancouver
Bills D, Benton B, Dabney W, Sellke TA. Quantitative evaluation of an artificial intelligence–driven remote monitoring system for occlusion assessment using patient-captured images. The Angle Orthodontist. 2026;96(6):659-666. doi:10.2319/010926-30.1
BibTeX
@article{Bills2026,
author = {Bills, Daniel and Benton, Barry and Dabney, William and Sellke, Terry A},
title = {Quantitative evaluation of an artificial intelligence–driven remote monitoring system for occlusion assessment using patient-captured images},
journal = {The Angle Orthodontist},
year = {2026},
volume = {96},
number = {6},
pages = {659--666},
doi = {10.2319/010926-30.1}
}
EUVIMED