EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Research on suitability of cooling capacity of cold storage area utilizing biogas as secondary refrigerant system

Enhai Liu, Biaocai Bai, Xiaoyong Wei, Mingguo Peng, Weibing Zhu, Yine Jiang, Gengyang Chen

Thermal Science · 2026 · 30 (2 Part A) · 1027-1038

DOI: 10.2298/tsci2602027l ↗

Kurz gefasst

Fachartikel in der Zeitschrift Thermal Science, 2026. Verfasst von Enhai Liu und 6 weiteren Autor:innen. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The biogas produced by the waste fruit and vegetable pile retting during the cold storage process is utilized. Subsequent to the decompression and purification treatment, a temperature control strategy is implemented in the enhanced cold storage area through the side load cooling cycle. The subsequent results demonstrate that the implementation of a biological natural gas cooling cycle, in conjunction with the criss-cross placement of shelves and a cargo frame tilt angle of 15?, as compared to shelf flat loading, results in a gradient distribution of regional temperature differences. This approach has been demonstrated to enhance the temperature uniformity index by 26.19%, increase the cooling rate by 3.36%, and reduce energy consumption by approximately 10.05%. Furthermore, the variation amplitude of the temperature non-uniformity coefficient of the shelf section is relatively gentle, with an average deviation of approximately 5.53%. The efficacy of this system in regulating temperature in time-sharing zones has been demonstrated. This system has been developed to facilitate the optimization of cold capacity, thereby ensuring the appropriate matching of cold storage capacity to the diverse needs of fruit and vegetable storage in different temperature zones.

Zitieren

APA

Liu, E., Bai, B., Wei, X., Peng, M., Zhu, W., Jiang, Y., & Chen, G. (2026). Research on suitability of cooling capacity of cold storage area utilizing biogas as secondary refrigerant system. Thermal Science, 30(2 Part A), 1027-1038. https://doi.org/10.2298/tsci2602027l

Vancouver

Liu E, Bai B, Wei X, Peng M, Zhu W, Jiang Y, et al. Research on suitability of cooling capacity of cold storage area utilizing biogas as secondary refrigerant system. Thermal Science. 2026;30(2 Part A):1027-1038. doi:10.2298/tsci2602027l

BibTeX
@article{Liu2026,
  author = {Liu, Enhai and Bai, Biaocai and Wei, Xiaoyong and Peng, Mingguo and Zhu, Weibing and Jiang, Yine and Chen, Gengyang},
  title = {Research on suitability of cooling capacity of cold storage area utilizing biogas as secondary refrigerant system},
  journal = {Thermal Science},
  year = {2026},
  volume = {30},
  number = {2 Part A},
  pages = {1027--1038},
  doi = {10.2298/tsci2602027l}
}
Kostenlos starten →