Establishment of the known radiation field calibration method utilizing a $ ^{137}\mathrm{Cs} $ radionuclide source reference radiation field according to ISO 4037:2019
Nuclear Technology and Radiation Protection · 2026 · 41 (2) · 159-166
DOI: 10.2298/ntrp2602159k ↗Kurz gefasst
Fachartikel in der Zeitschrift Nuclear Technology and Radiation Protection, 2026. Verfasst von Uk Kye und 8 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
A gamma irradiation system-based reference radiation field utilizing a ^{137}\mathrm{Cs} source has been established at the Dongnam Institute of Radiological and Medical Sciences to provide accredited calibration and reference radiation fields in accordance with ISO 4037-1:2019. The system was designed using Monte Carlo simulations (MCNP 6.2) to develop a conical collimator. Its performance was evaluated through a series of tests, including air kerma measurements, beam uniformity assessments, reproducibility tests, and analysis of scattered radiation contributions. The effective beam radius and beam profiles were characterized using ionization chambers and Gafchromic film, demonstrating strong agreement with simulation data. Air kerma rates were evaluated from 100 cm to 500 cm with two ^{137}\mathrm{Cs} sources (18.5 GBq and 370 GBq). Calibration equations were subsequently derived from these measurements. A reference air kerma rate of 3 mGyh ^{-1} was achieved at a distance of 2.568 m. The calibration coefficient was validated through a measurement audit conducted with the Korea Research Institute of Standards and Science, yielding an En-value of 0.08, indicating the system's high reliability and traceability. This study demonstrates that the established ^{137}\mathrm{Cs} irradiation system meets the relevant requirements of ISO 4037 for reference radiation fields and provides a reliable platform for calibrating and evaluating the performance of radiation protection instruments, including survey meters and personal dosimeters.
Zitieren
APA
Kye, U., Kim, H., Baek, J., Lee, G., Jo, W., Lee, J., Mok, S., Jang, H., & Kang, Y. (2026). Establishment of the known radiation field calibration method utilizing a $ ^{137}\mathrm{Cs} $ radionuclide source reference radiation field according to ISO 4037:2019. Nuclear Technology and Radiation Protection, 41(2), 159-166. https://doi.org/10.2298/ntrp2602159k
Vancouver
Kye U, Kim H, Baek J, Lee G, Jo W, Lee J, et al. Establishment of the known radiation field calibration method utilizing a $ ^{137}\mathrm{Cs} $ radionuclide source reference radiation field according to ISO 4037:2019. Nuclear Technology and Radiation Protection. 2026;41(2):159-166. doi:10.2298/ntrp2602159k
BibTeX
@article{Kye2026,
author = {Kye, Uk and Kim, Hyo and Baek, Jeong-Hwa and Lee, Geun and Jo, Wol and Lee, Ji and Mok, Seongyun and Jang, Hee and Kang, Yeong-Rok},
title = {Establishment of the known radiation field calibration method utilizing a $ ^137\mathrmCs $ radionuclide source reference radiation field according to ISO 4037:2019},
journal = {Nuclear Technology and Radiation Protection},
year = {2026},
volume = {41},
number = {2},
pages = {159--166},
doi = {10.2298/ntrp2602159k}
}