Investigating suboptimal performance of an oxidation ditch in a fecal sludge treatment plant: Impact of influent loading and aeration rate
Sustinere: Journal of Environment and Sustainability · 2026
DOI: 10.22515/njr48s93 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sustinere: Journal of Environment and Sustainability, 2026. Verfasst von Ervin Nurhayati und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Instalasi Pengolahan Lumpur Tinja (IPLT) Keputih is a 400 m³/day design capacity fecal sludge treatment plant (FSTP) in Surabaya that currently fails to meet national domestic wastewater quality standards. This study assesses how influent loading fluctuations and aeration rates, controlled by operating one or two mammoth rotors, affect the oxidation ditch unit's performance regarding pollutant removal and microbial growth. Results indicated that the influent organic loading rate (1.14–3.43 kg Biochemical Oxygen Demand (BOD)/m³.day) significantly exceeds the design capacity of 0.1–0.3 kg BOD/m³.day, resulting in residual organic matter and ineffective treatment. While dual-rotor operation provided high dissolved oxygen (DO) levels (4.37–6.72 mg/L), pollutant removal remained poor; the most efficient configuration only removed 33.43% of Chemical Oxygen Demand (COD), 25.85% of BOD, and 30.50% of Total Suspended Solids (TSS). Although oil and grease removal reached 76.58%, nitrogen removal was unsuccessful, with Total Kjeldahl Nitrogen (TKN) and NH₄⁺ concentrations actually increasing in some observations due to the absence of a denitrification process. Removal remained poor even where aeration was adequate, because the ditch carried an aged, overpopulated mixed liquor (MLSS 10,773–12,785 mg/L, two to six times typical) under a volumetric load far above the design range. Nitrogen removal failed because free-ammonia inhibition suppressed nitrification while ammonification continued, raising effluent NH₄⁺ and TKN concentrations. Meeting the standards requires controlled sludge wasting to restore the solids inventory and load equalization to relieve the organic overload, not aeration adjustment alone.
Zitieren
APA
Nurhayati, E., Ningayu, N. P. A., Rizal, M. N., Marhendra, B. A., & Puspitasari, C. D. (2026). Investigating suboptimal performance of an oxidation ditch in a fecal sludge treatment plant: Impact of influent loading and aeration rate. Sustinere: Journal of Environment and Sustainability. https://doi.org/10.22515/njr48s93
Vancouver
Nurhayati E, Ningayu NPA, Rizal MN, Marhendra BA, Puspitasari CD. Investigating suboptimal performance of an oxidation ditch in a fecal sludge treatment plant: Impact of influent loading and aeration rate. Sustinere: Journal of Environment and Sustainability. 2026. doi:10.22515/njr48s93
BibTeX
@article{Nurhayati2026,
author = {Nurhayati, Ervin and Ningayu, Nabilla Putri Arto and Rizal, Moh Najib and Marhendra, Bara Awanda and Puspitasari, Cynthia Dyah},
title = {Investigating suboptimal performance of an oxidation ditch in a fecal sludge treatment plant: Impact of influent loading and aeration rate},
journal = {Sustinere: Journal of Environment and Sustainability},
year = {2026},
doi = {10.22515/njr48s93}
}
EUVIMED