EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ziehl-Neelsen Smear Microscopy versus GeneXpert MTB/RIF for Diagnosing Pulmonary Tuberculosis: A Retrospective Diagnostic Accuracy Study from Nepal

Kishor Bajracharya, Laxmi Prasad Sapkota, Riwaaz Dhakal, Bardan Balami

Journal of Lumbini Medical College · 19.11.2026 · 14 (2) · 65-70

DOI: 10.22502/jlmc.v14i2.611 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Lumbini Medical College, online erschienen am 19.11.2026. Verfasst von Kishor Bajracharya und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Ziehl-Neelsen (ZN) sputum smear microscopy remains widely used for tuberculosis diagnosis in resource-limited settings, but its sensitivity is limited in paucibacillary disease. GeneXpert MTB/RIF offers higher sensitivity, yet real-world comparative data from Nepal remain scarce.

Methods

This retrospective, record-based cross-sectional study was conducted at Lumbini Medical College and Teaching Hospital, Palpa, Nepal. Records of 643 patients with presumptive pulmonary tuberculosis who underwent paired ZN smear microscopy and GeneXpert MTB/RIF testing were reviewed. Using GeneXpert as the reference standard, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall accuracy of ZN smear microscopy were calculated with 95% confidence intervals (Wilson method). Agreement was assessed by Cohen's kappa, and McNemar's test compared paired proportions. Receiver operating characteristic (ROC) curve analysis evaluated ZN smear grade discrimination.

Results

ZN smear microscopy was positive in 42 of 643 participants (6.53%) and GeneXpert in 61 (9.49%). ZN sensitivity was 68.85% (95% CI 56.41–79.06), specificity 100.00% (99.34–100.00), PPV 100.00% (91.62–100.00), NPV 96.84% (95.12–97.97), and overall accuracy 97.05% (95.43–98.10). Agreement was substantial (κ = 0.80; p < 0.001). The area under the ROC curve was 0.844. Rifampicin resistance was detected in 1 of 61 GeneXpert-positive samples (1.64%).

Conclusions

ZN smear microscopy showed high specificity but moderate sensitivity, missing one-third of GeneXpert-positive cases. GeneXpert MTB/RIF should remain the preferred initial diagnostic test where capacity allows.

Zitieren

APA

Bajracharya, K., Sapkota, L. P., Dhakal, R., & Balami, B. (2026). Ziehl-Neelsen Smear Microscopy versus GeneXpert MTB/RIF for Diagnosing Pulmonary Tuberculosis: A Retrospective Diagnostic Accuracy Study from Nepal. Journal of Lumbini Medical College, 14(2), 65-70. https://doi.org/10.22502/jlmc.v14i2.611

Vancouver

Bajracharya K, Sapkota LP, Dhakal R, Balami B. Ziehl-Neelsen Smear Microscopy versus GeneXpert MTB/RIF for Diagnosing Pulmonary Tuberculosis: A Retrospective Diagnostic Accuracy Study from Nepal. Journal of Lumbini Medical College. 2026;14(2):65-70. doi:10.22502/jlmc.v14i2.611

BibTeX
@article{Bajracharya2026,
  author = {Bajracharya, Kishor and Sapkota, Laxmi Prasad and Dhakal, Riwaaz and Balami, Bardan},
  title = {Ziehl-Neelsen Smear Microscopy versus GeneXpert MTB/RIF for Diagnosing Pulmonary Tuberculosis: A Retrospective Diagnostic Accuracy Study from Nepal},
  journal = {Journal of Lumbini Medical College},
  year = {2026},
  volume = {14},
  number = {2},
  pages = {65--70},
  doi = {10.22502/jlmc.v14i2.611}
}
Kostenlos starten →