EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 3.0

Semiautomated Analysis of Aortic Stenosis Parameters on Velocity-Encoded Phase-Contrast MR Images in Patients with Severe Aortic Stenosis: A Comparison with Echocardiography

So Hyeon Bak, Sung Mok Kim, Sung-Ji Park, Moon Young Kim, Hae Jin Kim, Sang-Chol Lee, Seung Woo Park, Yeon Hyeon Choe

Cardiovascular Imaging Asia · 2017

DOI: 10.22468/cvia.2016.00087 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cardiovascular Imaging Asia, 2017. Verfasst von So Hyeon Bak und 7 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The aim of the study was to determine the reliability of semiautomated analysis of aortic stenosis (AS) parameters on velocity-encoded (VENC) phase-contrast (PC) MR images in patients with severe AS. Materials and Methods:This study included 55 patients with severe AS and normal left ventricular ejection fraction who underwent transthoracic echocardiography (TTE) and VENC PC sequencing.Aortic valve area (AVA) and transvalvular velocity were measured semiautomatically with commercial software at three aortic valve levels [the level of the aortic leaflet tips (0 mm) and 6 mm upstream and downstream of the leaflet tips].The AVA was drawn on VENC PC images, and the maximum, minimum, and average were calculated.The peak and mean transaortic pressure gradient (PG) were calculated with a modified Bernoulli equation.All estimates were compared with TTE values by using the concordance correlation coefficient (CCC).

Results

Estimates at the 0 mm level were more highly correlated with TTE values (parameter, CCC): peak velocity, 0.394; average AVA, 0.735; maximum AVA, 0.538; peak PG, 0.539; and mean PG, 0.048.Among these parameters, average AVA0 mm had the highest reliability.

Conclusion

If AS parameters are measured on VENC PC sequences, average AVA0 mm should be considered as a parameter for diagnosing severe AS.

Zitieren

APA

Bak, S. H., Kim, S. M., Park, S., Kim, M. Y., Kim, H. J., Lee, S., Park, S. W., & Choe, Y. H. (2017). Semiautomated Analysis of Aortic Stenosis Parameters on Velocity-Encoded Phase-Contrast MR Images in Patients with Severe Aortic Stenosis: A Comparison with Echocardiography. Cardiovascular Imaging Asia. https://doi.org/10.22468/cvia.2016.00087

Vancouver

Bak SH, Kim SM, Park S, Kim MY, Kim HJ, Lee S, et al. Semiautomated Analysis of Aortic Stenosis Parameters on Velocity-Encoded Phase-Contrast MR Images in Patients with Severe Aortic Stenosis: A Comparison with Echocardiography. Cardiovascular Imaging Asia. 2017. doi:10.22468/cvia.2016.00087

BibTeX
@article{Bak2017,
  author = {Bak, So Hyeon and Kim, Sung Mok and Park, Sung-Ji and Kim, Moon Young and Kim, Hae Jin and Lee, Sang-Chol and Park, Seung Woo and Choe, Yeon Hyeon},
  title = {Semiautomated Analysis of Aortic Stenosis Parameters on Velocity-Encoded Phase-Contrast MR Images in Patients with Severe Aortic Stenosis: A Comparison with Echocardiography},
  journal = {Cardiovascular Imaging Asia},
  year = {2017},
  doi = {10.22468/cvia.2016.00087}
}
Kostenlos starten →