Modification of the rPLU5 Primer to Address Primer-Template Mismatch in a Plasmodium 2 Genus-Specific Nested PCR Assay

Yik-Zheng Lim, Boon-Teong Teoh, Nurul-Farhanah Hanuar, Noor-Syahida Azizan, Cheng-Hong Chua, Ummi-Syafiqah Rosmini, Wan-Nur-Athirah Muhammad-Ghazali, Juraina Abd-Jamil, Chee-Sieng Khor, Wei Yin Vinnie-Siow, Sing-Sin Sam, Van Lun Low und 1 weitere

Journal of Tropical One Health · 30.06.2026 · 1

DOI: 10.22452/jtoh.vol1.4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Tropical One Health, online erschienen am 30.06.2026. Verfasst von Yik-Zheng Lim und 12 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A primer-template mismatch was identified at the second nucleotide from the 3′ end of the nest 1 reverse primer (rPLU5) used in the Plasmodium genus-specific nested PCR assay developed by Singh et al. (1999). The mismatches near the 3′ end of primer have a strong destabilizing effect on primer annealing. Therefore, rPLU5 was modified (C→T substitution) and nested PCR was optimized using annealing temperature gradients: 55–65 °C for nest 1 and 60–70 °C for nest 2. Optimal amplification was observed at 59–63 °C for nest 1 and 60–66 °C for nest 2, with the lowest temperatures recommended to maximize sensitivity and specificity. Furthermore, the performance of original and modified rPLU5 was compared using Plasmodium-positive DNA samples extracted from human clinical specimen and macaque specimen. The original rPLU5 amplified only the macaque sample, whereas the modified rPLU5 successfully amplified both samples, indicating improved detection. However, given the limited number of samples and absence of species identification, this modification should be interpreted as a precautionary optimization to enhance assay robustness rather than a performance limitation of the original rPLU5. Overall, this work presents an optimized nested PCR assay incorporating an improved primer design that minimizes mismatch-related amplification issues.

Zitieren

APA

Lim, Y., Teoh, B., Hanuar, N., Azizan, N., Chua, C., Rosmini, U., Muhammad-Ghazali, W., Abd-Jamil, J., Khor, C., Vinnie-Siow, W. Y., Sam, S., Low, V. L., & AbuBakar, S. (2026). Modification of the rPLU5 Primer to Address Primer-Template Mismatch in a Plasmodium 2 Genus-Specific Nested PCR Assay. Journal of Tropical One Health, 1. https://doi.org/10.22452/jtoh.vol1.4

Vancouver

Lim Y, Teoh B, Hanuar N, Azizan N, Chua C, Rosmini U, et al. Modification of the rPLU5 Primer to Address Primer-Template Mismatch in a Plasmodium 2 Genus-Specific Nested PCR Assay. Journal of Tropical One Health. 2026;1. doi:10.22452/jtoh.vol1.4

BibTeX
@article{Lim2026,
  author = {Lim, Yik-Zheng and Teoh, Boon-Teong and Hanuar, Nurul-Farhanah and Azizan, Noor-Syahida and Chua, Cheng-Hong and Rosmini, Ummi-Syafiqah and Muhammad-Ghazali, Wan-Nur-Athirah and Abd-Jamil, Juraina and Khor, Chee-Sieng and Vinnie-Siow, Wei Yin and Sam, Sing-Sin and Low, Van Lun and AbuBakar, Sazaly},
  title = {Modification of the rPLU5 Primer to Address Primer-Template Mismatch in a Plasmodium 2 Genus-Specific Nested PCR Assay},
  journal = {Journal of Tropical One Health},
  year = {2026},
  volume = {1},
  doi = {10.22452/jtoh.vol1.4}
}
Kostenlos starten →