Performance evaluation of U-pipe type evacuated tube collector at low air flow rates: An experimental study
International Journal of Computational and Experimental Science and Engineering · 20.09.2025 · 11 (4)
DOI: 10.22399/ijcesen.5472 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Computational and Experimental Science and Engineering, online erschienen am 20.09.2025. Verfasst von Satish Kumar Gavel und 3 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Solar energy is regarded as one of the most favoured forms of renewable energy. Different researchers have proposed various kinds of solar collectors with distinct design changes and operating conditions. Among different types of solar collectors, the evacuated tube collector (ETC) stands out due to its significantly low convective heat losses from the absorber plate. The U-pipe setup within the evacuated tube is popular because of its straightforward design and ability to withstand the high pressure of the working fluid. Numerous theoretical and experimental investigations of U-pipe type ETC with diverse design alterations have been conducted by different researchers. An effort is made to assess the efficiency of a U-pipe type ETC for air flow rates between 1 kg/hr to 4 kg/hr. Experiments were conducted in Bilaspur, Chhattisgarh, India, during four distinct months from November 2024 to May 2025. The monthly average values of peak solar intensities were recorded as 950 W/m2, 973 W/m2, 1055 W/m2, and 1088 W/m2 for the months of November, February, April, and May, respectively. The peak rise in air temperature and the highest temperatures of copper fins were recorded at 63.7 °C and 179.9 °C, respectively, which corresponded to a mass flow rate of 1 kg/hr for the month of May; however, the greatest thermal efficiency observed was 36.6% at 4 kg/hr in the April. The maximum values of pressure drop and blower power were determined to be 0.30 KPa and 0.31 W, respectively, at a mass flow rate of 4 kg/hr.
Zitieren
APA
Gavel, S. K., Agrawal, G. K., Arjunan, T., & Kanwar, I. (2025). Performance evaluation of U-pipe type evacuated tube collector at low air flow rates: An experimental study. International Journal of Computational and Experimental Science and Engineering, 11(4). https://doi.org/10.22399/ijcesen.5472
Vancouver
Gavel SK, Agrawal GK, Arjunan T, Kanwar I. Performance evaluation of U-pipe type evacuated tube collector at low air flow rates: An experimental study. International Journal of Computational and Experimental Science and Engineering. 2025;11(4). doi:10.22399/ijcesen.5472
BibTeX
@article{Gavel2025,
author = {Gavel, Satish Kumar and Agrawal, Gajendra Kumar and Arjunan, T.V. and Kanwar, Indulata},
title = {Performance evaluation of U-pipe type evacuated tube collector at low air flow rates: An experimental study},
journal = {International Journal of Computational and Experimental Science and Engineering},
year = {2025},
volume = {11},
number = {4},
doi = {10.22399/ijcesen.5472}
}
EUVIMED