EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Performance and Exergy Analysis of Cryogenic Cycles

Hüsniye Çeker, Erman Kadir Öztekin, Arzu Keven, Rabi Karaali

International Journal of Computational and Experimental Science and Engineering · 18.05.2026 · 12 (2)

DOI: 10.22399/ijcesen.5244 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Computational and Experimental Science and Engineering, online erschienen am 18.05.2026. Verfasst von Hüsniye Çeker und 3 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study examines and demonstrates the concepts of thermodynamics, exergy, and exergy analysis, and shows how these principles are applied to cryogenic cycles using equations. Furthermore, an energy, exergy, and performance analyses of the two-stage vapor compression cascade cryogenic cycle for natural gas liquefaction is conducted, and optimum operating conditions are presented in tables. Based on the data obtained from these equations, exergy analysis of cryogenic cycles was performed, and performance analysis and curves were plotted. When the compressor outlet pressures of the first sub cycle is increased from 3300 kPa to 4590 kPa, the exergy loss of the devices decreases, the exergy efficiencies of the increases, and the COP values ​​increase. When the cooling amount in heat exchangers 1 and 2 is increased from 9 °C to 17 °C, i.e., when cooling is increased, it leads to a slight improvement in the performance of the system. The optimum total compressor consumption according to inlet/outlet temperature difference in heat exchangers 1 and 2 are obtained at about 14-15 °C. When these two improvement methods are applied together, optimum performance values ​​of the system are obtained. The COP value increases from 0.078 to 0.1164. The system is affected by the compressor outlet pressure of the first sub cycle. Increasing the cooling level from 9°C to 17°C in heat exchangers 1 and 2 has a minor impact on system performance.

Zitieren

APA

Çeker, H., Öztekin, E. K., Keven, A., & Karaali, R. (2026). Performance and Exergy Analysis of Cryogenic Cycles. International Journal of Computational and Experimental Science and Engineering, 12(2). https://doi.org/10.22399/ijcesen.5244

Vancouver

Çeker H, Öztekin EK, Keven A, Karaali R. Performance and Exergy Analysis of Cryogenic Cycles. International Journal of Computational and Experimental Science and Engineering. 2026;12(2). doi:10.22399/ijcesen.5244

BibTeX
@article{eker2026,
  author = {Çeker, Hüsniye and Öztekin, Erman Kadir and Keven, Arzu and Karaali, Rabi},
  title = {Performance and Exergy Analysis of Cryogenic Cycles},
  journal = {International Journal of Computational and Experimental Science and Engineering},
  year = {2026},
  volume = {12},
  number = {2},
  doi = {10.22399/ijcesen.5244}
}
Kostenlos starten →