Earth-Air Heat Exchanger Systems for Energy Efficiency Enhancement in Algerian Residential Buildings: A Multi-Climate Zone Analysis

Khiera Ben Babba, Mohammed Sellami, Sellami Ali

International Journal of Computational and Experimental Science and Engineering · 03.03.2026 · 12 (1)

DOI: 10.22399/ijcesen.3979 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Computational and Experimental Science and Engineering, online erschienen am 03.03.2026. Verfasst von Khiera Ben Babba und 2 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates Earth-Air Heat Exchanger (EAHE) systems for improving energy efficiency in Algerian residential buildings across diverse climatic zones. Algeria's climate conditions, ranging from Mediterranean coastal areas to hot arid desert regions, present unique challenges for passive cooling and heating technologies. This research analyzes EAHE performance in three representative cities: Tamanrasset (hot arid), Constantine (semi-arid Mediterranean), and Adrar (hot desert), using comprehensive meteorological data and building energy simulation models. The study employs mathematical modeling incorporating heat transfer analysis, soil thermal properties, and building energy dynamics. Monthly and hourly analyses used actual climate data with ambient temperatures ranging from 7.5°C to 35.5°C and solar irradiation values from 5.4 to 12.2 MJ/m²/day. The modeled EAHE system consists of 100-meter underground pipes buried at 3-meter depth, serving typical 150 m² residential buildings. Results demonstrate significant energy efficiency improvements across all climate zones. Annual energy savings ranged from 24.2% (Constantine, 1,892 kWh) to 31.3% (Adrar, 3,156 kWh), with Tamanrasset achieving 28.5% reduction (2,847 kWh). EAHE effectiveness values ranged from 65% to 82%, with peak performance during extreme ambient conditions. Hourly analysis revealed 4-8°C temperature reductions at EAHE outlets during peak summer, significantly reducing cooling loads. Economic analysis indicates annual cost savings of $427-$473 per household with 6-8 year payback periods, demonstrating economic viability. This research contributes practical guidelines for EAHE implementation in North African residential buildings, supporting earth-coupled heat exchange systems as effective strategies for reducing energy consumption and enhancing thermal comfort in Algeria's challenging climates.

Zitieren

APA

Babba, K. B., Sellami, M., & Ali, S. (2026). Earth-Air Heat Exchanger Systems for Energy Efficiency Enhancement in Algerian Residential Buildings: A Multi-Climate Zone Analysis. International Journal of Computational and Experimental Science and Engineering, 12(1). https://doi.org/10.22399/ijcesen.3979

Vancouver

Babba KB, Sellami M, Ali S. Earth-Air Heat Exchanger Systems for Energy Efficiency Enhancement in Algerian Residential Buildings: A Multi-Climate Zone Analysis. International Journal of Computational and Experimental Science and Engineering. 2026;12(1). doi:10.22399/ijcesen.3979

BibTeX
@article{Babba2026,
  author = {Babba, Khiera Ben and Sellami, Mohammed and Ali, Sellami},
  title = {Earth-Air Heat Exchanger Systems for Energy Efficiency Enhancement in Algerian Residential Buildings: A Multi-Climate Zone Analysis},
  journal = {International Journal of Computational and Experimental Science and Engineering},
  year = {2026},
  volume = {12},
  number = {1},
  doi = {10.22399/ijcesen.3979}
}
Kostenlos starten →