Design and Implementation of a Portable Air Quality Monitoring Device Using Nova Fitness SDS011 Sensor Technology in Urban Areas

Naza Fahrul Sirait, Sri Nengsih

Jurnal Phi : Jurnal Pendidikan Fisika dan Fisika Terapan · 19.07.2026 · 12 (2) · 332-343

DOI: 10.22373/p-jpft.v12i2.32124 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Jurnal Phi : Jurnal Pendidikan Fisika dan Fisika Terapan, online erschienen am 19.07.2026. Verfasst von Naza Fahrul Sirait und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents the design and implementation of a portable air-quality monitoring device based on the Nova Fitness SDS011 sensor to measure PM2.5 concentrations. The system integrates a microcontroller-based processing unit with real-time data display and audio warning features. Device performance was evaluated by calibrating against a reference instrument (BAM 1020, BMKG), yielding an average measurement error of 2.43%. In addition, validation by media experts indicated a high feasibility level of 95%, confirming the device’s suitability for practical use. Field testing conducted in several urban locations revealed significant variations in PM2.5 concentration, influenced by factors such as traffic density, industrial activity, and population distribution. The results demonstrate that the proposed device provides a reliable, low-cost, and portable solution for real-time PM2.5 monitoring in urban environments. This study contributes to the development of easy-to-use tools for monitoring air quality in support of environmental awareness and educational applications.

Zitieren

APA

Sirait, N. F., & Nengsih, S. (2026). Design and Implementation of a Portable Air Quality Monitoring Device Using Nova Fitness SDS011 Sensor Technology in Urban Areas. Jurnal Phi : Jurnal Pendidikan Fisika dan Fisika Terapan, 12(2), 332-343. https://doi.org/10.22373/p-jpft.v12i2.32124

Vancouver

Sirait NF, Nengsih S. Design and Implementation of a Portable Air Quality Monitoring Device Using Nova Fitness SDS011 Sensor Technology in Urban Areas. Jurnal Phi : Jurnal Pendidikan Fisika dan Fisika Terapan. 2026;12(2):332-343. doi:10.22373/p-jpft.v12i2.32124

BibTeX
@article{Sirait2026,
  author = {Sirait, Naza Fahrul and Nengsih, Sri},
  title = {Design and Implementation of a Portable Air Quality Monitoring Device Using Nova Fitness SDS011 Sensor Technology in Urban Areas},
  journal = {Jurnal Phi : Jurnal Pendidikan Fisika dan Fisika Terapan},
  year = {2026},
  volume = {12},
  number = {2},
  pages = {332--343},
  doi = {10.22373/p-jpft.v12i2.32124}
}