Fachartikel in der Zeitschrift Romanian Journal of Ophthalmology, 2024. Verfasst von Kodavoor Shreesha Kumar und 3 weiteren Autor:innen. Beteiligte Einrichtung: The Eye Foundation, Coimbatore, Tamil Nadu, India. Hauptthemen laut MEDLINE: Capsulorhexis, Cataract, Visual Acuity, Lens Capsule, Crystalline. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

Completing circular uniform anterior capsulorhexis in intumescent white cataracts is challenging for all cataract surgeons. Numerous techniques have been described to get a circular capsulorhexis and prevent perpendicular linear tears in the anterior capsule.

Methods

570 cases of white total cataracts were selected for this retrospective clinical study. In this technique of Star CanVac rhexis, the anterior lens capsule was nicked using a 26 G cystotome, and multiple centripetal tears were made in the center to create a small star-shaped opening. A vacuum was used to develop capsulorhexis, and a 25 G flat tip cannula attached to a 5 ml syringe half filled with balanced salt solution (BSS) was used to build capsulorhexis. The piston of the 5 ml syringe was withdrawn to create a vacuum to hold the free capsular flap. It was then directed circularly to get a round capsulorhexis. Oozing liquefied cortex was aspirated simultaneously with the same cannula.

Results

This technique was successfully executed in 564 eyes. Six eyes had anterior capsular tears, 2 of which extended into the posterior capsule.

Discussion

Intumescent cataracts often complicate the rhexis procedure due to increased lens volume and pressure. Over time, different methods have been refined to handle the pressure variation between the anterior chamber and the intralenticular area, such as mini-rhexis, double rhexis, sewing needle capsulotomy, and phaco capsulotomy. The primary goal of these procedures is to first reduce the elevated intralenticular pressure. Star CanVac capsulotomy facilitates equal pressure between the anterior chamber and the lenticular compartment, effectively reducing the risk of accidental capsular tears. Advantages of this approach include completing rhexis in one step, removing the liquefied cortex simultaneously, and relying on easily accessible instruments.

Conclusion

Star CanVac capsulorhexis is an effective, safe, and alternative technique to conventional capsulorhexis in total white cataracts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CapsulorhexisCataractVisual AcuityLens Capsule, CrystallineHumansRetrospective StudiesAgedFemaleMaleMiddle AgedAged, 80 and over

Stichwörter der Autor:innen

BSS = Balanced salt solutionCCC = continuous curvilinear capsulorhexisCME = Cystoid Macular EdemaIOL = Intraocular lensOVD = Ophthalmic Viscoelastic DeviceSICS = Small Incision Cataract SurgeryStar CanVacintumescent cataractvacuum rhexis

Autor:innen und Institutionen

  • The Eye Foundation, Coimbatore, Tamil Nadu, India.

Zitieren

APA

Kumar, K. S., Sumithra, R., Tamilarasi, S., & Ramamurthy, D. (2024). Star Can Vac Capsulorhexis in White Total Cataracts - A Retrospective Interventional Analysis. Romanian Journal of Ophthalmology. https://doi.org/10.22336/rjo.2024.73

Vancouver

Kumar KS, Sumithra R, Tamilarasi S, Ramamurthy D. Star Can Vac Capsulorhexis in White Total Cataracts - A Retrospective Interventional Analysis. Romanian Journal of Ophthalmology. 2024. doi:10.22336/rjo.2024.73

BibTeX
@article{Kumar2024,
  author = {Kumar, Kodavoor Shreesha and Sumithra, Raju and Tamilarasi, S and Ramamurthy, Dandapani},
  title = {Star Can Vac Capsulorhexis in White Total Cataracts - A Retrospective Interventional Analysis},
  journal = {Romanian Journal of Ophthalmology},
  year = {2024},
  doi = {10.22336/rjo.2024.73}
}
Kostenlos starten →