EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access

Efficacy and safety of the OZil phacoemulsification handpiece in dropped lens fragment surgery: a randomized controlled trial

Vipin Rana, Deependra Kumar Sinha, Meenu Dangi, Atul Gupta, Sandepan Bandopadhyay, Jaya Kaushik, Ashok Kumar, Amit Nandan Tripathi

Romanian Journal of Ophthalmology · 2024

DOI: 10.22336/rjo.2024.52 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Romanian Journal of Ophthalmology, 2024. Verfasst von Vipin Rana und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Command Hospital (Eastern Command), Kolkata, India. Hauptthemen laut MEDLINE: Phacoemulsification, Visual Acuity. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Phacoemulsification is the predominant method for cataract surgery, but complications like lens nuclei dislodgment into the vitreous cavity pose significant risks, including inflammation, glaucoma, retinal tears, and vision loss. Traditional management involves pars plana vitrectomy with phacofragmentation, which can increase the risk of retinal damage due to repulsive forces. This study tests whether the OZil phacoemulsification handpiece, employing torsional movement, offers a safer alternative by minimizing repulsive forces and reducing surgical duration compared to the traditional phacofragmatome.

Methods

This prospective study, conducted in a tertiary care hospital in eastern India from January to June 2023, enrolled 40 patients with nucleus dislocation during cataract surgery. Patients were randomized into Group 1 (traditional phacofragmatome) and Group 2 (OZil handpiece). Primary objectives included comparing the duration of surgery and intraoperative complications. Secondary objectives assessed postoperative best-corrected visual acuity (BCVA), surgical site safety, and cystoid macular edema (CME) incidence.

Results

Group 2 demonstrated significantly shorter surgical durations (110±2.54 seconds) compared to Group 1 (152±2.23 seconds, p < 0.001). The frequency of nucleus falls was considerably lower in Group 2 (p < 0.001). Postoperative BCVA and CME incidence showed no significant differences between groups. Multiple regression analysis confirmed the OZil handpiece significantly reduced surgical duration (β = -0.40, p < 0.001) without compromising safety.

Discussion

The OZil handpiece's rotational cutting mechanism offers a significant advantage in reducing surgical time while improving the followability of lens fragments, as compared to the traditional phacofragmatome. It addresses one of the key limitations of phacofragmentation by minimizing fragment displacement, where repulsive forces can complicate the procedure. Although both techniques showed similar safety profiles, the OZil handpiece's operational efficiency makes it a promising alternative for managing posteriorly displaced lens fragments in complex cases.

Conclusions

The OZil phacoemulsification handpiece significantly enhances surgical efficiency and safety in nucleus drop surgeries. Its integration into existing phacofragmatome systems can lead to major advancement in the ophthalmic surgical armamentarium, ensuring improved patient care.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhacoemulsificationVisual AcuityHumansMaleFemaleProspective StudiesMiddle AgedAgedLens SubluxationTreatment OutcomeIntraoperative ComplicationsFollow-Up StudiesPostoperative Complications

Stichwörter der Autor:innen

BCVA = Best corrected visual acuityCME = Cystoid macular edemaOZilPFCLs = Perfluorocarbon liquidsPPV = Pars plana vitrectomycataractnucleus dropphacoemulsificationphacofragmentation

Autor:innen und Institutionen

  • Department of Ophthalmology, Command Hospital (Eastern Command), Kolkata, India.
  • Department of Anaesthesia, Command Hospital (Eastern Command), Kolkata, India.
  • Department of Ophthalmology, Command Hospital (Central Command), Lucknow, India.
  • Western Eye Hospital, London, United Kingdom.
  • Department of Ophthalmology, Armed Forces Medical College, Pune, Maharashtra, India.

Zitieren

APA

Rana, V., Sinha, D. K., Dangi, M., Gupta, A., Bandopadhyay, S., Kaushik, J., Kumar, A., & Tripathi, A. N. (2024). Efficacy and safety of the OZil phacoemulsification handpiece in dropped lens fragment surgery: a randomized controlled trial. Romanian Journal of Ophthalmology. https://doi.org/10.22336/rjo.2024.52

Vancouver

Rana V, Sinha DK, Dangi M, Gupta A, Bandopadhyay S, Kaushik J, et al. Efficacy and safety of the OZil phacoemulsification handpiece in dropped lens fragment surgery: a randomized controlled trial. Romanian Journal of Ophthalmology. 2024. doi:10.22336/rjo.2024.52

BibTeX
@article{Rana2024,
  author = {Rana, Vipin and Sinha, Deependra Kumar and Dangi, Meenu and Gupta, Atul and Bandopadhyay, Sandepan and Kaushik, Jaya and Kumar, Ashok and Tripathi, Amit Nandan},
  title = {Efficacy and safety of the OZil phacoemulsification handpiece in dropped lens fragment surgery: a randomized controlled trial},
  journal = {Romanian Journal of Ophthalmology},
  year = {2024},
  doi = {10.22336/rjo.2024.52}
}
Kostenlos starten →