Streamlining VMAT-TBI: A Single CT Scan Workflow for Enhanced Clinical Efficiency and Dosimetric Precision
Journal of Contemporary Medical Sciences · 26.04.2026 · 12 (2)
DOI: 10.22317/jcms.v12i2.2111 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Contemporary Medical Sciences, online erschienen am 26.04.2026. Verfasst von Shaima Shoeir und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objectives
To report the implementation and dosimetric evaluation of a single-CT, size-adapted VMAT-TBI workflow designed to simplify planning and treatment delivery across a heterogeneous cohort of pediatric and adult patients undergoing total body irradiation for transplant conditioning. Unlike more complex multi-scan or specialized-platform approaches, this workflow was developed to provide a practical and reproducible clinical solution using standard linear accelerator infrastructure.
Methods
Sixty-seven patients treated with 1200 cGy in 5 fractions between December 2020 and July 2024 were retrospectively analyzed. Patients were assigned to three workflow groups according to body size: Group A (height ≤135 cm), Group B (height >135 cm), and Group C (body width >40 cm). All patients underwent a single head-first supine CT simulation. Treatment plans were generated in Monaco using multi-isocenter VMAT; taller patients received supplementary (anterior and posterior) AP/PA open fields for the lower extremities, and broader patients were planned using dual partial-arc arrangements. Dosimetric endpoints, organ-at-risk doses, workflow timing, and patient-specific quality assurance results were evaluated descriptively.
Results
The workflow was successfully implemented across all patient groups. Mean PTV D95 was 94.6%, 94.0%, and 94.0% for Groups A, B, and C, respectively, with limited high-dose volumes (V110%: 0.35%, 1.5%, and 1.3%). Mean lung doses remained below 920 cGy across groups, and kidney, heart, thyroid, liver, and lens doses were maintained within institutional planning objectives. Average planning time was approximately 12 hours. Mean beam-on treatment time for the VMAT component was 16.6 ± 3.1 minutes for shorter patients, 18.2 ± 1.8 minutes for taller patients, and 25.4 ± 2.5 minutes for broader patients. Quality assurance demonstrated acceptable agreement between planned and measured dose delivery.
Conclusion
This study demonstrates the feasibility of a single-CT, size-adapted VMAT-TBI workflow that provides reproducible target coverage, organ sparing, and manageable planning and treatment times in a relatively large mixed-age cohort. The principal contribution of this work lies in the practical standardization of VMAT-TBI implementation rather than the introduction of a novel irradiation technique. Clinical outcomes were not analyzed in the present study and should be addressed in future work.
Zitieren
APA
Shoeir, S., Elgebaly, R. H., Monem, S. A., Ammar, H., & Zaghloul, M. S. (2026). Streamlining VMAT-TBI: A Single CT Scan Workflow for Enhanced Clinical Efficiency and Dosimetric Precision. Journal of Contemporary Medical Sciences, 12(2). https://doi.org/10.22317/jcms.v12i2.2111
Vancouver
Shoeir S, Elgebaly RH, Monem SA, Ammar H, Zaghloul MS. Streamlining VMAT-TBI: A Single CT Scan Workflow for Enhanced Clinical Efficiency and Dosimetric Precision. Journal of Contemporary Medical Sciences. 2026;12(2). doi:10.22317/jcms.v12i2.2111
BibTeX
@article{Shoeir2026,
author = {Shoeir, Shaima and Elgebaly, Reem H and Monem, Soltan A. and Ammar, Hany and Zaghloul, Mohamed S.},
title = {Streamlining VMAT-TBI: A Single CT Scan Workflow for Enhanced Clinical Efficiency and Dosimetric Precision},
journal = {Journal of Contemporary Medical Sciences},
year = {2026},
volume = {12},
number = {2},
doi = {10.22317/jcms.v12i2.2111}
}
EUVIMED