Integration of ISO 14971 Requirements into the Design Processes of Class III Life-Sustaining Medical Devices

Sandeep Reddy Koppula

International Journal of Advanced Engineering, Management and Science · 2026 · 12 (2) · 142-148

DOI: 10.22161/ijaems.122.17 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Advanced Engineering, Management and Science, 2026. Verfasst von Sandeep Reddy Koppula.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

his article examines how ISO 14971 requirements can be embedded into the design processes of Class III life-sustaining medical devices as an operating design discipline. The subject is relevant because implantable and life-sustaining systems combine severe clinical consequences of failure with complex interactions among materials, software, mechanical components, and use conditions. The aim is to develop an analytical model for integrating risk management into design planning, evidence generation, and lifecycle control. The study relies on recent scientific and regulatory publications focused on high-risk devices, implantable systems, quality system regulation, post-market surveillance, cybersecurity, and clinical evaluation. Comparative analysis, conceptual synthesis, and analytical generalization were used. The analytical part shows that effective integration requires early hazard framing, traceability between risk controls and verification evidence, and continuous transfer of post-market signals into design change logic. The proposed interpretation has practical value for quality engineering, design reviews, and regulatory readiness of Class III medical technologies.

Zitieren

APA

Koppula, S. R. (2026). Integration of ISO 14971 Requirements into the Design Processes of Class III Life-Sustaining Medical Devices. International Journal of Advanced Engineering, Management and Science, 12(2), 142-148. https://doi.org/10.22161/ijaems.122.17

Vancouver

Koppula SR. Integration of ISO 14971 Requirements into the Design Processes of Class III Life-Sustaining Medical Devices. International Journal of Advanced Engineering, Management and Science. 2026;12(2):142-148. doi:10.22161/ijaems.122.17

BibTeX
@article{Koppula2026,
  author = {Koppula, Sandeep Reddy},
  title = {Integration of ISO 14971 Requirements into the Design Processes of Class III Life-Sustaining Medical Devices},
  journal = {International Journal of Advanced Engineering, Management and Science},
  year = {2026},
  volume = {12},
  number = {2},
  pages = {142--148},
  doi = {10.22161/ijaems.122.17}
}
Kostenlos starten →