EUVIMEDEUVIMED entdecken
Crossref

Quantitative CT Measurements of Interstitial Lung Disease: Same-Day Variability Between Two Vendors—A Prospective Study

Yura Ahn, Sang Min Lee, Youngjae Kim, Hyunna Lee, Jang Ho Lee, Ho Cheol Kim, Joon Beom Seo

American Journal of Roentgenology · 2026

DOI: 10.2214/ajr.25.34057 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Roentgenology, 2026. Verfasst von Yura Ahn und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Song…. Hauptthemen laut MEDLINE: Lung Diseases, Interstitial, Tomography, X-Ray Computed, Tomography Scanners, X-Ray Computed. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND. Clinical application of quantitative CT (QCT) measurements of interstitial lung disease (ILD) for longitudinal monitoring of disease progression requires an understanding of how such measurements vary across vendors. OBJECTIVE. The purpose of this study was to evaluate same-day variability between vendors for QCT measurements of fibrosis extent in patients with ILD. METHODS. This prospective study recruited participants with ILD diagnosed from January 2023 to November 2023. Participants underwent two serial unenhanced chest CT examinations on the same day using scanners from two different vendors (Discovery CT750 HD [GE HealthCare] and Somatom Definition AS+ [Siemens Healthineers]), with examinations separated by approximately 15 minutes. Examinations were reconstructed using three kernels (lung, chest, and bone) from GE Healthcare and three kernels (B60f, B50f, and B30f) from Siemens Healthineers. The lung and B60f kernels represented each vendor's primary high-frequency kernel for ILD evaluation. Commercially available deep learning-based software was used for QCT analysis. The fibrosis score was calculated as the sum of reticular opacity and honeycombing volume percentages. Intervendor variability was assessed using the Bland-Altman method, and agreement was assessed using the concordance correlation coefficient (CCC). RESULTS. The study included 48 participants (43 men and five women; mean age, 67.8 ± 5.2 [SD] years). The mean fibrosis score for the lung and B60f kernels was 12.64% and 11.84%, respectively. For the fibrosis score, the mean raw difference ranged from a minimum for the bone-B50f kernel pair (0.11%; 95% limits of agreement [LOA], -1.3% to 1.5%) to a maximum for the lung-B30f kernel pair (-2.52%; 95% LOA, -6.5% to 1.4%). The lung-B60f kernel pair showed a mean raw difference of -0.80% (95% LOA, -3.4% to 1.8%). The 95% LOA was narrowest for the bone-B50f kernel pair and widest for the lung-B30f kernel pair. The fibrosis score demonstrated substantial to almost perfect agreement across all intervendor kernel combinations (CCC, 0.953-0.998), including almost perfect agreement for the lung-B60f kernel pair (CCC, 0.989). CONCLUSION. QCT-derived fibrosis scores showed small variability (mean raw difference, -0.80%) for same-day CT examinations performed using systems from two different vendors when reconstructed with each vendor's primary high-frequency kernel for lung evaluation. CLINICAL IMPACT. QCT-derived fibrosis scores across different vendors may be informative for longitudinal assessment of ILD when interpreted in the context of expected measurement variability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lung Diseases, InterstitialTomography, X-Ray ComputedTomography Scanners, X-Ray ComputedHumansProspective StudiesMaleFemaleMiddle AgedAgedLungRadiographic Image Interpretation, Computer-AssistedReproducibility of Results

Stichwörter der Autor:innen

CTbiasinterstitial lung diseasepulmonary fibrosisquantification

Autor:innen und Institutionen

  • Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Republic of Korea.
  • Department of Biomedical Engineering, AMIST, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Bigdata Research Center, Asan Institute for Life Science, Asan Medical Center, Seoul, Republic of Korea.
  • Department of Pulmonary and Critical Care Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.

Zitieren

APA

Ahn, Y., Lee, S. M., Kim, Y., Lee, H., Lee, J. H., Kim, H. C., & Seo, J. B. (2026). Quantitative CT Measurements of Interstitial Lung Disease: Same-Day Variability Between Two Vendors—A Prospective Study. American Journal of Roentgenology. https://doi.org/10.2214/ajr.25.34057

Vancouver

Ahn Y, Lee SM, Kim Y, Lee H, Lee JH, Kim HC, et al. Quantitative CT Measurements of Interstitial Lung Disease: Same-Day Variability Between Two Vendors—A Prospective Study. American Journal of Roentgenology. 2026. doi:10.2214/ajr.25.34057

BibTeX
@article{Ahn2026,
  author = {Ahn, Yura and Lee, Sang Min and Kim, Youngjae and Lee, Hyunna and Lee, Jang Ho and Kim, Ho Cheol and Seo, Joon Beom},
  title = {Quantitative CT Measurements of Interstitial Lung Disease: Same-Day Variability Between Two Vendors—A Prospective Study},
  journal = {American Journal of Roentgenology},
  year = {2026},
  doi = {10.2214/ajr.25.34057}
}
Kostenlos starten →