Spectral Photon-Counting Detector Coronary CTA With Reduced Radiation and Contrast Medium Dose in Inflammation-Associated Coronary Artery Disease: A Prospective Study
American Journal of Roentgenology · 2025
DOI: 10.2214/ajr.25.33493 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Roentgenology, 2025. Verfasst von Cheng Xu und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical …. Hauptthemen laut MEDLINE: Contrast Media, Coronary Artery Disease, Coronary Angiography, Computed Tomography Angiography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 39 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND. Patients with inflammation-associated coronary artery disease (CAD) may exhibit rapid progression and require regular coronary imaging. OBJECTIVE. The purpose of this article was to evaluate the diagnostic performance of spectral photon-counting detector (PCD) coronary CTA with reduced radiation and contrast medium dose for detecting coronary stenosis and in-stent restenosis in patients with inflammation-associated CAD. METHODS. This prospective study enrolled patients with inflammation-associated CAD from January 2022 to March 2024. Participants underwent spectral PCD coronary CTA using prospectively ECG-triggered sequential acquisition and an individualized low-dose contrast medium protocol. Images were reconstructed with virtual monoenergetic imaging (VMI) at 55 keV and polychromatic (T3D) imaging using matching parameters, including 0.4-mm slice thickness. Two readers independently assessed subjective (5-point Likert scales) and objective image quality measures; readers also assessed images for obstructive stenosis and in-stent restenosis (both ≥ 50%) in patients with invasive coronary angiography (ICA) available as a reference. RESULTS. The analysis included 63 patients (mean age, 50.4 ± 11.5 [SD] years; 45 women, 18 men). Median contrast medium volume was 28.0 mL. Median DLP was 165.0 mGy ∙ cm. Images from 55-keV VMI, compared with those from T3D imaging, showed better (p .05) in accuracy for in-stent restenosis (reader 1: 97.3% vs 96.0%; reader 2: 96.0% vs 94.7%). CONCLUSION. Spectral PCD coronary CTA, performed using low radiation and contrast medium dose and reconstructed using 55-keV VMI, showed excellent diagnostic accuracy in detecting obstructive stenosis and in-stent restenosis in patients with inflammation-associated CAD. CLINICAL IMPACT. The proposed protocol could be used to guide clinical decision-making in inflammation-associated CAD.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, No. 1, Shuaifuyuan, Dongche…
- Department of Cardiology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
- CT Collaboration, Siemens Healthineers, Beijing, China.
- Department of CT, Siemens Healthineers, Forchheim, Germany.
- Department of Radiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
Zitieren
APA
Xu, C., Sun, Y., Wang, L., Zou, L., Wang, M., Lin, L., Wang, Y., Sun, X., Liu, X., Yu, X., Leidecker, C., Wang, L., Liu, Y., Qian, H., Tian, R., Vliegenthart, R., Liu, Z., & Wang, Y. (2025). Spectral Photon-Counting Detector Coronary CTA With Reduced Radiation and Contrast Medium Dose in Inflammation-Associated Coronary Artery Disease: A Prospective Study. American Journal of Roentgenology. https://doi.org/10.2214/ajr.25.33493
Vancouver
Xu C, Sun Y, Wang L, Zou L, Wang M, Lin L, et al. Spectral Photon-Counting Detector Coronary CTA With Reduced Radiation and Contrast Medium Dose in Inflammation-Associated Coronary Artery Disease: A Prospective Study. American Journal of Roentgenology. 2025. doi:10.2214/ajr.25.33493
BibTeX
@article{Xu2025,
author = {Xu, Cheng and Sun, Yue and Wang, Liang and Zou, Limiao and Wang, Ming and Lin, Lu and Wang, Yun and Sun, Xiaonan and Liu, Xiaoying and Yu, Xianbo and Leidecker, Christianne and Wang, Lun and Liu, Yifan and Qian, Hao and Tian, Ran and Vliegenthart, Rozemarijn and Liu, Zhenyu and Wang, Yining},
title = {Spectral Photon-Counting Detector Coronary CTA With Reduced Radiation and Contrast Medium Dose in Inflammation-Associated Coronary Artery Disease: A Prospective Study},
journal = {American Journal of Roentgenology},
year = {2025},
doi = {10.2214/ajr.25.33493}
}
EUVIMED