EUVIMEDEUVIMED entdecken
Vergleichsstudie

Neonatal Anthropometric Measurements: A Comparison of Neonates With 3-T Fetal MRI Exposure, With 1.5-T Fetal MRI Exposure, and Without In-Utero MRI Exposure

Enrico Danzer, Valeria Peña-Trujillo, Sebastian Gallo-Bernal, Michael S Gee, Teresa Victoria

American Journal of Roentgenology · 2024

DOI: 10.2214/ajr.24.31647 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift American Journal of Roentgenology, 2024. Verfasst von Enrico Danzer und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Division of Pediatric Surgery, Memorial Sloan Kettering Cancer Center, Weill Cornell Medical College, New York, NY. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Anthropometry. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND. Fetal MRI is increasingly performed at 3 T. Nonetheless, safety concerns persist regarding potential increased risk of intrauterine growth restriction from in-utero 3-T MRI exposure. OBJECTIVE. The purpose of this study was to compare neonatal anthropometric measurements between neonates who underwent 3-T fetal MRI, neonates who underwent 1.5-T fetal MRI, and neonates without in-utero MRI exposure. METHODS. This single-center retrospective study included gravid patients who underwent fetal ultrasound and possible 1.5-T or 3-T fetal MRI within 10 days between January 2017 and January 2022. For each included patient who also underwent 3-T fetal MRI, one matched patient who also underwent 1.5-T MRI and two matched patients without in-utero MRI exposure were randomly selected. Matching was based on gestational age at the time of the fetal ultrasound. Neonatal anthropometric characteristics were compared among groups. RESULTS. The final sample included 416 patients (mean age, 32 ± 5 [SD] years), 104 in the 3-T MRI group, 104 in the 1.5-T MRI group, and 208 in the MRI-unexposed group. The mean gestational age at the time of fetal ultrasound used for matching was 27 weeks 2 days in the 3-T group, 25 weeks 2 days in the 1.5-T group, and 26 weeks 0 days in the MRI-unexposed group (p = .07). The distribution of indications for fetal MRI was not significantly different between the 3-T and 1.5-T groups (p = .56). The mean gestational age at delivery was 37 weeks 5 days in the 3-T group, 38 weeks 0 days in the 1.5-T group, and 38 weeks 2 days in the unexposed group (p = .51). No significant difference was observed among the groups in mean neonatal weight (3 T: 3120 ± 753 [SD] g; 1.5 T: 3104 ± 704 g; unexposed: 2967 ± 614 g; p = .09), mean neonatal weight percentile (3 T: 45 ± 27 [SD]; 1.5 T: 42 ± 26; unexposed: 41 ± 24; p = .56), mean neonatal head circumference (3 T: 34 ± 3 [SD] cm; 1.5 T: 34 ± 3 cm; unexposed: 34 ± 2 cm; p = .05), or mean neonatal head circumference percentile (3 T: 48 ± 29 [SD]; 1.5 T: 42 ± 23; unexposed: 43 ± 30; p = .32). CONCLUSION. There were no significant differences in neonatal anthropometric measurements among neonates who underwent in-utero 3-T MRI, neonates who underwent in-utero 1.5-T MRI, and neonates without in-utero MRI exposure. CLINICAL IMPACT. The results support the safety of 3-T MRI with respect to the growth of the developing fetus.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingAnthropometryHumansFemaleInfant, NewbornRetrospective StudiesPregnancyMaleAdultUltrasonography, PrenatalGestational AgeBirth WeightFetal Growth RetardationPrenatal Diagnosis

Stichwörter der Autor:innen

3 TMRIanthropometricsfetusprenatal imagingsafety

Autor:innen und Institutionen

  • Department of Surgery, Division of Pediatric Surgery, Memorial Sloan Kettering Cancer Center, Weill Cornell Medical College, New York, NY.
  • Department of Pediatrics, Division of Neonatal and Developmental Medicine, Stanford University School of Medicine and Lucile Packard Children's Hospital, Palo Alto, CA.
  • Department of Pediatric Imaging, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114.
  • Pediatric Imaging Research Center, Massachusetts General Hospital, Boston, MA.
  • Department of Medicine, NYC Health + Hospitals, Icahn School of Medicine at Mount Sinai, New York, NY.

Zitieren

APA

Danzer, E., Peña-Trujillo, V., Gallo-Bernal, S., Gee, M. S., & Victoria, T. (2024). Neonatal Anthropometric Measurements: A Comparison of Neonates With 3-T Fetal MRI Exposure, With 1.5-T Fetal MRI Exposure, and Without In-Utero MRI Exposure. American Journal of Roentgenology. https://doi.org/10.2214/ajr.24.31647

Vancouver

Danzer E, Peña-Trujillo V, Gallo-Bernal S, Gee MS, Victoria T. Neonatal Anthropometric Measurements: A Comparison of Neonates With 3-T Fetal MRI Exposure, With 1.5-T Fetal MRI Exposure, and Without In-Utero MRI Exposure. American Journal of Roentgenology. 2024. doi:10.2214/ajr.24.31647

BibTeX
@article{Danzer2024,
  author = {Danzer, Enrico and Peña-Trujillo, Valeria and Gallo-Bernal, Sebastian and Gee, Michael S and Victoria, Teresa},
  title = {Neonatal Anthropometric Measurements: A Comparison of Neonates With 3-T Fetal MRI Exposure, With 1.5-T Fetal MRI Exposure, and Without In-Utero MRI Exposure},
  journal = {American Journal of Roentgenology},
  year = {2024},
  doi = {10.2214/ajr.24.31647}
}
Kostenlos starten →