High-Frequency Jet Ventilation Versus Spontaneous Respiration for Percutaneous Cryoablation of Lung Tumors: Comparison of Adverse Events and Procedural Efficiency
American Journal of Roentgenology · 2024
DOI: 10.2214/ajr.23.30557 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift American Journal of Roentgenology, 2024. Verfasst von Alexander Graur und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Division of Thoracic Imaging and Intervention, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114. Hauptthemen laut MEDLINE: High-Frequency Jet Ventilation, Lung Neoplasms, Cryosurgery. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 49 Literaturangaben.
Themen: Patientensicherheit
Abstract (Originalsprache)
BACKGROUND. High-frequency jet ventilation (HFJV) facilitates accurate probe placement in percutaneous ablation of lung tumors but may increase risk for adverse events, including systemic air embolism. OBJECTIVE. The purpose of this study was to compare major adverse events and procedural efficiency of percutaneous lung ablation with HFJV under general anesthesia to spontaneous respiration (SR) under moderate sedation. METHODS. This retrospective study included consecutive adults who underwent CT-guided percutaneous cryoablation of one or more lung tumors with HFJV or SR between January 1, 2017, and May 31, 2023. We compared major adverse events (Common Terminology Criteria for Adverse Events grade ≥ 3) within 30 days postprocedure and hospital length of stay (HLOS) of 2 days or more using logistic regression analysis. We compared procedure time, room time, CT guidance acquisition time, CT guidance radiation dose, total radiation dose, and pneumothorax using generalized estimating equations. RESULTS. Overall, 139 patients (85 women, 54 men; median age, 68 years) with 310 lung tumors (82% metastases) underwent 208 cryoablations (HFJV, n = 129; SR, n = 79). HFJV showed greater rates than SR for the treatment of multiple tumors per session (43% vs 19%, respectively; p = .02) and tumors in a nonperipheral location (48% vs 24%, p .05). Room time was longer for HFJV than SR (median, 154 vs 127 minutes, p .05). CONCLUSION. HFJV appears to be as safe as SR but had longer room times. HFJV can be used in complex cases without significantly impacting HLOS of 2 days or more, procedure time, or radiation exposure. CLINICAL IMPACT. Selection of the ventilation modality during percutaneous lung ablation should be based on patient characteristics and anticipated procedural requirements as well as operator preference.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Division of Thoracic Imaging and Intervention, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114.
- Department of Radiology, Ludwig-Maximilians-University, Munich, Germany.
- Department of Radiology, Massachusetts General Hospital, Boston, MA.
- Department of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
- Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, MA.
Zitieren
APA
Graur, A., Mercaldo, N. D., Simon, J., Alici, C., Saenger, J. A., Cahalane, A. M., Vazquez, R., & Fintelmann, F. J. (2024). High-Frequency Jet Ventilation Versus Spontaneous Respiration for Percutaneous Cryoablation of Lung Tumors: Comparison of Adverse Events and Procedural Efficiency. American Journal of Roentgenology. https://doi.org/10.2214/ajr.23.30557
Vancouver
Graur A, Mercaldo ND, Simon J, Alici C, Saenger JA, Cahalane AM, et al. High-Frequency Jet Ventilation Versus Spontaneous Respiration for Percutaneous Cryoablation of Lung Tumors: Comparison of Adverse Events and Procedural Efficiency. American Journal of Roentgenology. 2024. doi:10.2214/ajr.23.30557
BibTeX
@article{Graur2024,
author = {Graur, Alexander and Mercaldo, Nathaniel D and Simon, Judit and Alici, Cagatay and Saenger, Jonathan A and Cahalane, Alexis M and Vazquez, Rafael and Fintelmann, Florian J},
title = {High-Frequency Jet Ventilation Versus Spontaneous Respiration for Percutaneous Cryoablation of Lung Tumors: Comparison of Adverse Events and Procedural Efficiency},
journal = {American Journal of Roentgenology},
year = {2024},
doi = {10.2214/ajr.23.30557}
}
EUVIMED