EUVIMEDEUVIMED entdecken
Crossref

Basic Finite Element Analysis of Para-periodontal Ligament in All-ceramic Zirconia Fixed Partial Denture

Syuntaro Nomoto, Satoru Matsunaga, Toru Sato, Mamoru Yotsuya, Shinichi Abe

The Bulletin of Tokyo Dental College · 2015 · 56 (4) · 215-222

DOI: 10.2209/tdcpublication.56.215 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Bulletin of Tokyo Dental College, 2015. Verfasst von Syuntaro Nomoto und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Fixed Prosthodontics, Tokyo Dental College. Hauptthemen laut MEDLINE: Ceramics, Denture Design, Denture, Partial, Fixed, Periodontal Ligament. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The purpose of the present study was to investigate the validity of incorporating a para-periodontal ligament in the test mold used in a basic fracture test of a zirconia all-ceramic fixed partial denture (FPD). A simplified three-dimensional finite element analysis model was designed based on the three-unit FPD fracture test. Two types of model, one with and one without a para-periodontal ligament between the abutment and base mold, were fabricated. Microfocus CT of the missing first molar area in a dry human mandible was performed. A three-dimensional model was then fabricated based on the data obtained. A load of 600 N was applied to the center of the pontic and stress distribution observed. The model with the para-periodontal ligament showed stress dispersion to the dental root with rotation of the abutment mold. Stress distribution in the finite element analysis model with a para-periodontal ligament showed greater similarity with that in the mandibular model than with that in the other two models without a para-periodontal ligament.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CeramicsDenture DesignDenture, Partial, FixedPeriodontal LigamentDental AbutmentsDental Stress AnalysisFinite Element AnalysisHumansStress, Mechanical

Autor:innen und Institutionen

  • Department of Fixed Prosthodontics, Tokyo Dental College.

Zitieren

APA

Nomoto, S., Matsunaga, S., Sato, T., Yotsuya, M., & Abe, S. (2015). Basic Finite Element Analysis of Para-periodontal Ligament in All-ceramic Zirconia Fixed Partial Denture. The Bulletin of Tokyo Dental College, 56(4), 215-222. https://doi.org/10.2209/tdcpublication.56.215

Vancouver

Nomoto S, Matsunaga S, Sato T, Yotsuya M, Abe S. Basic Finite Element Analysis of Para-periodontal Ligament in All-ceramic Zirconia Fixed Partial Denture. The Bulletin of Tokyo Dental College. 2015;56(4):215-222. doi:10.2209/tdcpublication.56.215

BibTeX
@article{Nomoto2015,
  author = {Nomoto, Syuntaro and Matsunaga, Satoru and Sato, Toru and Yotsuya, Mamoru and Abe, Shinichi},
  title = {Basic Finite Element Analysis of Para-periodontal Ligament in All-ceramic Zirconia Fixed Partial Denture},
  journal = {The Bulletin of Tokyo Dental College},
  year = {2015},
  volume = {56},
  number = {4},
  pages = {215--222},
  doi = {10.2209/tdcpublication.56.215}
}
Kostenlos starten →