Minimalist Approach for HoLEP with A Low-Power Holmium Source: A Retrospective Study.
Urology journal./Urology jornal. · 09.09.2025 · 22 (3) · 164-168
DOI: 10.22037/uj.v21i.8071 ↗Kurz gefasst
Fachartikel in der Zeitschrift Urology journal./Urology jornal., erschienen am 09.09.2025. Verfasst von Ramazan Inan und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Medova Hospital, Konya, Turkey. ramazaninan86@gmail.com. Hauptthemen laut MEDLINE: Lasers, Solid-State, Prostatic Hyperplasia, Prostatectomy, Laser Therapy. Die Arbeit wurde bisher 1-mal zitiert (Crossref).
Abstract (Originalsprache)
PURPOSE: To assess the efficacy and safety of very low-power Holmium Laser Enucleation of the Prostate (HoLEP) on a 30-W holmium laser source. MATERIALS AND METHODS: With the approval of the local ethics committee, we retrospectively analysed 60 patients treated with HoLEP. There were 30 patients in the low-power (LP) group and 30 patients in the very low-power (VLP) group. For the LP group, we used a 60-W holmium laser machine. Throughout the en bloc process, we used laser settings of 2 J and 20 Hz. We used a 30-W low-power holmium source in the VLP group. We used laser settings of 2 J and 10 Hz. All patients were operated on by an experienced surgeon. We evaluated the surgical parameters and practicality of the low-power laser vs. the very low-power laser. RESULTS: All patients underwent successful HoLEP in the very low-power group; it was not necessary to increase the output of the laser in any case. Mean preoperatively estimated prostate volume was 88.1 mL (range, 30-300 mL). Mean enucleation time and enucleation efficiency were 67.9 min (range, 25-150 min) and 0.99 gm/min (range, 0.8-1.8 gm/min), respectively. No patient required blood transfusion postoperatively. No stress urinary incontinence (SUI) was observed in the 3rd month postoperative follow-up. CONCLUSION: The use of a low-power laser source is encouraging for the learning curve of new surgeons who will begin HoLEP surgery; it can facilitate the adoption of HoLEP in developing countries, where the initial capital investment may be a major obstacle.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Urology, Medova Hospital, Konya, Turkey. ramazaninan86@gmail.com.
- Department of Urology, Medova Hospital, Konya, Turkey. ibrahimbuldu@yahoo.com.
Zitieren
APA
Inan, R., & Buldu, I. (2025). Minimalist Approach for HoLEP with A Low-Power Holmium Source: A Retrospective Study. Urology journal./Urology jornal., 22(3), 164-168. https://doi.org/10.22037/uj.v21i.8071
Vancouver
Inan R, Buldu I. Minimalist Approach for HoLEP with A Low-Power Holmium Source: A Retrospective Study. Urology journal./Urology jornal.. 2025;22(3):164-168. doi:10.22037/uj.v21i.8071
BibTeX
@article{Inan2025,
author = {Inan, Ramazan and Buldu, Ibrahim},
title = {Minimalist Approach for HoLEP with A Low-Power Holmium Source: A Retrospective Study},
journal = {Urology journal./Urology jornal.},
year = {2025},
volume = {22},
number = {3},
pages = {164--168},
doi = {10.22037/uj.v21i.8071}
}