EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitSystematische ÜbersichtMetaanalyseOpen Access

Revisiting the Diagnostic Accuracy of Ottawa Ankle Rules for Ankle Fractures: A Systematic Review and Meta-Analysis.

Danial Sharifi Razavi, Mohammadali Seiri, Mehrdad Farrokhi

Archives of Academic Emergency Medicine · 01.01.2026 · 14 (1) · e24-e24

DOI: 10.22037/aaem.v14i1.3051 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Archives of Academic Emergency Medicine, erschienen am 01.01.2026. Verfasst von Danial Sharifi Razavi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The Ottawa Ankle Rules (OAR) have demonstrated conflicting results across studies, with generally high sensitivity but relatively low and variable specificity. This updated meta-analysis aims to evaluate the overall diagnostic characteristics of the OAR for early identification of ankle fractures in adult patients.

Methods

In this systematic review and meta-analysis, a comprehensive literature search was conducted from database inception through May 2026 across three electronic databases, including Medline, Web of Science, and Scopus. The MIDAS package in STATA and Meta-Disc software were used to pool the findings of the diagnostic accuracy studies. Clinical application of the OAR was assessed using Fagan's nomogram and scattergram.

Results

The pooled sensitivity and specificity of OAR were 0.92 (95% confidence interval (CI): 0.91-0.93) and 0.35 (95% CI: 0.34-0.36), respectively. The pooled positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 1.76 (95% CI: 1.46-2.13) and 0.13 (95% CI: 0.09-0.19), respectively. Furthermore, the pooled diagnostic odds ratio (DOR) was 16.21 (95% CI: 10.15-25.89).

Conclusion

In conclusion, the OAR demonstrate excellent sensitivity and a very low negative likelihood ratio, confirming their value as a reliable screening tool for ruling out ankle fractures in clinical practice. With pooled sensitivities exceeding 90% and a post-test probability reduced to approximately 1% following a negative result, the OAR can safely reduce unnecessary radiographic imaging.

Schlagwörter

Stichwörter der Autor:innen

Ankle FracturesAnkle InjuriesClinical Decision RulesMeta-analysis

Autor:innen und Institutionen

  • Department of Orthopedics, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
  • Department of Orthopedics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran.
  • ERIS Research Institute, Tehran, Iran.
  • Department of Epidemiology, School of Public Health and Safety, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

Zitieren

APA

Sharifi Razavi, D., Seiri, M., & Farrokhi, M. (2026). Revisiting the Diagnostic Accuracy of Ottawa Ankle Rules for Ankle Fractures: A Systematic Review and Meta-Analysis. Archives of Academic Emergency Medicine, 14(1), e24-e24. https://doi.org/10.22037/aaem.v14i1.3051

Vancouver

Sharifi Razavi D, Seiri M, Farrokhi M. Revisiting the Diagnostic Accuracy of Ottawa Ankle Rules for Ankle Fractures: A Systematic Review and Meta-Analysis. Archives of Academic Emergency Medicine. 2026;14(1):e24-e24. doi:10.22037/aaem.v14i1.3051

BibTeX
@article{SharifiRazavi2026,
  author = {Sharifi Razavi, Danial and Seiri, Mohammadali and Farrokhi, Mehrdad},
  title = {Revisiting the Diagnostic Accuracy of Ottawa Ankle Rules for Ankle Fractures: A Systematic Review and Meta-Analysis},
  journal = {Archives of Academic Emergency Medicine},
  year = {2026},
  volume = {14},
  number = {1},
  pages = {e24--e24},
  doi = {10.22037/aaem.v14i1.3051}
}
Kostenlos starten →