Comparing the Accuracy of Patient-Perceived Fever, Manual Fever Checking, and Non-Contact Frontal Infrared Thermometer; A Cross-sectional Study.
Archives of Academic Emergency Medicine · 01.01.2026 · 14 (1) · e7-e7
DOI: 10.22037/aaem.v14i1.2883 ↗Kurz gefasst
Querschnittstudie in der Zeitschrift Archives of Academic Emergency Medicine, erschienen am 01.01.2026. Verfasst von Moojan Shabani-Kakroudi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Emergency Medicine Department, Imam Khomeini Hospital Complex (IKHC), Tehran University of Medical Science (TUMS), School of Medicine, Tehran, Iran. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Introduction
Non-contact frontal infrared thermometers (NCFITs) have gained popularity following the COVID-19 pandemic, but their accuracy remains debated. This study compared the accuracy of three index tests of patient-perceived fever (PPF), manual fever checking (MFC) by emergency nurses, and NCFIT against tympanic thermometer (TT).
Methods
This single center, diagnostic accuracy study evaluated adult patients in the triage area of the emergency department (ED) between May and September 2023. Five emergency nurses (ENs) examined patients using convenience sampling with index tests, followed by TT measurement for fever detection as standard test (T≥38°C). The sensitivity, specificity, positive and negative likelihood ratios (PLR and NLR) and accuracy, of PPF, MFC, and NCFIT in detecting the fever were measured and reported with 95% confidence interval (CI). The inter-rater reliability of ENs for MFC among 10 patients (outside the study) was 100%.
Results
We included 279 patients with the mean age of 52.2 ± 16.98 years (51.97% male). TT identified 147 as febrile and 132 as non-febrile. The most sensitive index test was MFC, achieving 100% (95%CI: 97.5-100.0) sensitivity, 0 NLR, and 8.25 (95%CI: 5.7-12.1) PLR, with moderate accuracy (93.9% (95%CI: 89.9-96.0)). NCFIT demonstrated the lowest sensitivity (85.71% (95%CI: 78.9-90.9)) but the highest specificity (98.48% (95%CI: 93.6-99.5)) and accuracy (97.5% (95%CI: 93.1-99.8)). When the fever threshold for NCFIT was lowered to 37.5°C, sensitivity increased to 99% (95%CI: 97.4-99.9), NLR decreased to 0.01 (95%CI: 0-0.6), and PLR rose to 49.5 (95%CI: 20.8-90.2), while specificity remained at 98% (95%CI: 94-99.6).
Conclusion
MFC/PPF could rule out fever but required NCFIT/TT to rule it in. However, NCFIT achieved the highest NLR and PLR when its fever threshold was set at 37.5 °C.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Emergency Medicine Department, Imam Khomeini Hospital Complex (IKHC), Tehran University of Medical Science (TUMS), School of Medicine, Tehran, Iran.
- Department of Community Medicine, Tehran University of Medical Science (TUMS), School of Medicine, Tehran, Iran.
- Emergency Medicine Department, Shariati hospital, Tehran University of Medical Science (TUMS), School of Medicine, Tehran, Iran.
- Department of Orthopedic Surgery & Musculoskeletal Medicine, University of Otago, Christchurch, New Zealand.
Zitieren
APA
Shabani-Kakroudi, M., Jalili, M., Meysamie, A. P., Akhgar, A., Akbari, H., Zangi, M., Aligholi Zahraie, M., Aqavil-Jahromi, S., & Eftekhari, M. (2026). Comparing the Accuracy of Patient-Perceived Fever, Manual Fever Checking, and Non-Contact Frontal Infrared Thermometer; A Cross-sectional Study. Archives of Academic Emergency Medicine, 14(1), e7-e7. https://doi.org/10.22037/aaem.v14i1.2883
Vancouver
Shabani-Kakroudi M, Jalili M, Meysamie AP, Akhgar A, Akbari H, Zangi M, et al. Comparing the Accuracy of Patient-Perceived Fever, Manual Fever Checking, and Non-Contact Frontal Infrared Thermometer; A Cross-sectional Study. Archives of Academic Emergency Medicine. 2026;14(1):e7-e7. doi:10.22037/aaem.v14i1.2883
BibTeX
@article{ShabaniKakroudi2026,
author = {Shabani-Kakroudi, Moojan and Jalili, Mohammad and Meysamie, Ali Pasha and Akhgar, Atousa and Akbari, Hamideh and Zangi, Mahdi and Aligholi Zahraie, Mehrnoosh and Aqavil-Jahromi, Saeed and Eftekhari, Mohammad},
title = {Comparing the Accuracy of Patient-Perceived Fever, Manual Fever Checking, and Non-Contact Frontal Infrared Thermometer; A Cross-sectional Study},
journal = {Archives of Academic Emergency Medicine},
year = {2026},
volume = {14},
number = {1},
pages = {e7--e7},
doi = {10.22037/aaem.v14i1.2883}
}
EUVIMED