Health Dataspace Technology Acceptance Model (HDS-TAM): Development and Case Evaluation Study of Patient Acceptance of Germany’s Electronic Patient Record
JMIR Medical Informatics · 02.11.2026 · 14 · e99366-e99366
DOI: 10.2196/99366 ↗Kurz gefasst
Fachartikel in der Zeitschrift JMIR Medical Informatics, online erschienen am 02.11.2026. Verfasst von Veronika Vasileva und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Software Technology, Faculty of Computer Science, Universität Koblenz, Universitätsstr. 1, Koblenz, Rheinland-Pfalz, 56070, Germany, 49…. Hauptthemen laut MEDLINE: Electronic Health Records, Patient Acceptance of Health Care, Attitude to Computers. Die Arbeit nennt 68 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
The European Health Dataspace (EHDS) expands health data sharing beyond direct care and introduces governance, transparency, trust, and secondary-use considerations that are not fully captured by established technology acceptance models such as the Technology Acceptance Model (TAM) and the Unified Theory of Acceptance and Use of Technology (UTAUT). To address this gap, we developed the health dataspace technology acceptance model (HDS-TAM) and evaluated it using the German electronic patient record (ePA) as an illustrative health dataspace (HDS) application.
Objective
This study aimed (1) to derive an HDS-oriented technology acceptance framework from the literature and (2) to assess its applicability in explaining acceptance of the ePA from a patient perspective.
Methods
A structured literature review screened 1788 records, reviewed 134 full-text papers, and retained 68 studies for model development. HDS-TAM was subsequently applied in a scenario-based online survey conducted between March and April 2025. Of 235 questionnaire accesses and 163 submitted responses, 149 valid responses were analyzed. Data were analyzed using multiple imputation, exploratory factor analysis, and partial least squares structural equation modeling (PLS-SEM). The association between behavioral intention and actual ePA use was examined using logistic regression.
Results
The model explained 75.9% of the variance in behavioral intention to use (BI, R ²=0.759), 67% in perceived usefulness (PU, R ²=0.670), and 54% in perceived risk (PR, R ²=0.540). PU showed the strongest positive association with BI ( β =.670, P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute for Software Technology, Faculty of Computer Science, Universität Koblenz, Universitätsstr. 1, Koblenz, Rheinland-Pfalz, 56070, Germany, 49 2612870.
- Healthcare, Fraunhofer Institute for Software and Systems Engineering, Dortmund, North Rhine-Westphalia, Germany.
Zitieren
APA
Vasileva, V., Wolf, E., Riediger, V., Ahmadian, A. S., Buschmann, D., & Jürjens, J. (2026). Health Dataspace Technology Acceptance Model (HDS-TAM): Development and Case Evaluation Study of Patient Acceptance of Germany’s Electronic Patient Record. JMIR Medical Informatics, 14, e99366-e99366. https://doi.org/10.2196/99366
Vancouver
Vasileva V, Wolf E, Riediger V, Ahmadian AS, Buschmann D, Jürjens J. Health Dataspace Technology Acceptance Model (HDS-TAM): Development and Case Evaluation Study of Patient Acceptance of Germany’s Electronic Patient Record. JMIR Medical Informatics. 2026;14:e99366-e99366. doi:10.2196/99366
BibTeX
@article{Vasileva2026,
author = {Vasileva, Veronika and Wolf, Eduard and Riediger, Volker and Ahmadian, Amir Shayan and Buschmann, Daniel and Jürjens, Jan},
title = {Health Dataspace Technology Acceptance Model (HDS-TAM): Development and Case Evaluation Study of Patient Acceptance of Germany’s Electronic Patient Record},
journal = {JMIR Medical Informatics},
year = {2026},
volume = {14},
pages = {e99366--e99366},
doi = {10.2196/99366}
}
EUVIMED