A Quantifiable 3D Closed-Loop Framework for Controlled Substance Safety in a HIMSS Electronic Medical Record Adoption Model (EMRAM) Stage 7 Hospital: Pre-Post Quality Improvement Study
JMIR Medical Informatics · 2026
DOI: 10.2196/98247 ↗Kurz gefasst
Fachartikel in der Zeitschrift JMIR Medical Informatics, 2026. Verfasst von Nasha Sun und 4 weiteren Autor:innen. Beteiligte Einrichtung: Ningbo Hospital of Integrated Traditional Chinese and Western Medicine, Yinzhou District Second Hospital, Ningbo, Zhejiang, China. Hauptthemen laut MEDLINE: Electronic Health Records, Quality Improvement, Controlled Substances. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Controlled substances require strict life cycle management, but manual workflows can lead to documentation errors, traceability gaps, and delays in empty-ampoule recovery.
Objective
This study aimed to construct a quantifiable 3D closed-loop framework integrating technology, process redesign, and organizational accountability and to examine whether implementation was temporally associated with changes in controlled substance process indicators.
Methods
A single-center pre-post quality improvement study was conducted in a Healthcare Information and Management Systems Society (HIMSS) Electronic Medical Record Adoption Model (EMRAM) stage 7 hospital. The preintervention period was September 2024 to November 2024, and the postintervention period was December 2024 to February 2025. The intervention combined unique drug identifiers, personal digital assistant (PDA)–based bedside verification, smart medication cabinets, predispensing prescription review rules, batch-number traceability, daily reconciliation, tiered alerts, staff training, and anomaly-handling standard operating procedures (SOPs). Outcomes were prescription dispensing record compliance, batch-number management noncompliance, failure to complete empty-ampoule recovery and electronic documentation within 24 hours, and implementation fidelity. Proportions were reported with Wilson 95% CIs. Between-period absolute differences and 95% CIs were calculated using the Wald normal approximation for independent proportions. Comparisons used the chi-square test or Fisher exact test, as appropriate.
Results
The analysis included 3264 prescription dispensing records before implementation and 3311 prescription dispensing records after implementation. Prescription dispensing record compliance increased from 94.82% (3095/3264) to 98.7% (3268/3311). Batch-number management noncompliance decreased from 2.4% (24/1000) to 0.6% (6/1000). The rate of failure to complete empty-ampoule recovery and electronic documentation within 24 hours decreased from 5.61% (68/1213) to 0.78% (10/1274). Implementation fidelity indicators generated from operational logs were high across system stability, scanning execution, and anomaly closure.
Conclusions
Implementation of the 3D closed-loop framework was temporally associated with improvements in controlled substance process indicators in a digitally mature hospital. The implementation parameters may serve as a reference for local feasibility testing in other wards or institutions, but transferability remains to be evaluated. Multicenter studies are still needed to confirm sustainability and transferability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Ningbo Hospital of Integrated Traditional Chinese and Western Medicine, Yinzhou District Second Hospital, Ningbo, Zhejiang, China.
ORCID-Profile: Nasha Sun, Jihua Su, Qiyi Yu, Yong Xu, Mali Zhuo
Zitieren
APA
Sun, N., Su, J., Yu, Q., Xu, Y., & Zhuo, M. (2026). A Quantifiable 3D Closed-Loop Framework for Controlled Substance Safety in a HIMSS Electronic Medical Record Adoption Model (EMRAM) Stage 7 Hospital: Pre-Post Quality Improvement Study. JMIR Medical Informatics. https://doi.org/10.2196/98247
Vancouver
Sun N, Su J, Yu Q, Xu Y, Zhuo M. A Quantifiable 3D Closed-Loop Framework for Controlled Substance Safety in a HIMSS Electronic Medical Record Adoption Model (EMRAM) Stage 7 Hospital: Pre-Post Quality Improvement Study. JMIR Medical Informatics. 2026. doi:10.2196/98247
BibTeX
@article{Sun2026,
author = {Sun, Nasha and Su, Jihua and Yu, Qiyi and Xu, Yong and Zhuo, Mali},
title = {A Quantifiable 3D Closed-Loop Framework for Controlled Substance Safety in a HIMSS Electronic Medical Record Adoption Model (EMRAM) Stage 7 Hospital: Pre-Post Quality Improvement Study},
journal = {JMIR Medical Informatics},
year = {2026},
doi = {10.2196/98247}
}
EUVIMED