Comparative Efficacy of Different AI Systems for Polyp Detection by Size During Colonoscopy: Systematic Review and Network Meta-Analysis
Journal of Medical Internet Research · 09.09.2026 · 28 · e95841
DOI: 10.2196/95841 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Journal of Medical Internet Research, online erschienen am 09.09.2026. Verfasst von Ling Ba und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Hepatology, Tianjin Medical University General Hospital, Tianjin, China. Hauptthemen laut MEDLINE: Colonoscopy, Colonic Polyps, Artificial Intelligence. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Colorectal cancer remains a leading cause of death despite being largely preventable through polypectomy. AI systems designed to enhance polyp detection during colonoscopy have shown promise, but the extent to which they improve detection of different-sized polyps remains unclear.
Objective
This study compared the size-stratified efficacy of AI-assisted colonoscopy vs standard colonoscopy using the Hartung-Knapp-Sidik-Jonkman (HKSJ) method, and generated exploratory rankings while acknowledging all cross-platform comparisons are indirect.
Methods
This systematic review and network meta-analysis (NMA) searched PubMed, Embase, Cochrane CENTRAL, and Web of Science from inception to July 25, 2026, supplemented by citation searching. We included randomized controlled trials (RCTs) comparing AI-assisted vs standard colonoscopy in adults (≥18 years of age), reporting mean polyp detection counts stratified by size (≤5 mm, 6-9 mm, and ≥10 mm). Two reviewers screened studies, extracted data, and assessed risk of bias using the Cochrane Risk of Bias 2.0. We conducted frequentist NMA using the HKSJ method with restricted maximum likelihood estimation, calculated 95% prediction intervals (PIs), and assessed heterogeneity using I2 and τ2. Certainty of evidence was rated using the GRADE (Grading of Recommendations Assessment, Development, and Evaluation) framework.
Results
A total of 13 RCTs (4156 participants) compared 8 AI systems to standard colonoscopy, forming a network without direct AI comparisons. For diminutive polyps (≤5 mm), AI showed a modest advantage (standardized mean difference [SMD] 0.21, 95% CI 0.07 to 0.35, 95% PI –1.12 to 1.54), but substantial heterogeneity (I2=86.6%) and wide PI crossing the null indicated high uncertainty. EndoScreener showed the most consistent evidence (SMD 0.36, 95% CI 0.18-0.54). For small and large polyps, effects were minimal (SMD 0.02, 95% CI –0.02 to 0.06, 95% PI –0.03 to 0.07; SMD 0.01, 95% CI 0.00-0.02, 95% PI –0.01 to 0.03). GRADE certainty was very low for diminutive polyps and low for small and large polyps. Sensitivity analysis excluding Tianjin YuJin did not materially change findings.
Conclusions
AI may modestly enhance diminutive polyp detection, but effects on small and large polyps are minimal, with no platform superiority. Given very low to low certainty, findings are hypothesis-generating. This exploratory NMA provides size-stratified comparisons that can inform future head-to-head trial design. Unlike prior reviews aggregating all polyp sizes, we show the overall AI benefit is driven by diminutive polyp detection, providing a framework for targeted deployment—prioritizing AI for diminutive polyp screening, with limited value for larger lesions. Head-to-head trials are urgently needed. Trial Registration PROSPERO International Prospective Register of Systematic Reviews CRD420251266932; https://www.crd.york.ac.uk/PROSPERO/view/CRD420251266932
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Gastroenterology and Hepatology, Tianjin Medical University General Hospital, Tianjin, China.
- Tianjin Yujin Artifcial Intelligence Medical Technology Co.,Ltd., Tianjin, China.
ORCID-Profile: Ling Ba, Yaxin Qi, Xinrui Lv, Sipu Wang, Lu Yang, Yufeng Wang, Bangmao Wang, Hailong Cao, Xin Xu
Zitieren
APA
Ba, L., Qi, Y., Lv, X., Wang, S., Yang, L., Wang, Y., Wang, B., Cao, H., & Xu, X. (2026). Comparative Efficacy of Different AI Systems for Polyp Detection by Size During Colonoscopy: Systematic Review and Network Meta-Analysis. Journal of Medical Internet Research, 28, e95841. https://doi.org/10.2196/95841
Vancouver
Ba L, Qi Y, Lv X, Wang S, Yang L, Wang Y, et al. Comparative Efficacy of Different AI Systems for Polyp Detection by Size During Colonoscopy: Systematic Review and Network Meta-Analysis. Journal of Medical Internet Research. 2026;28:e95841. doi:10.2196/95841
BibTeX
@article{Ba2026,
author = {Ba, Ling and Qi, Yaxin and Lv, Xinrui and Wang, Sipu and Yang, Lu and Wang, Yufeng and Wang, Bangmao and Cao, Hailong and Xu, Xin},
title = {Comparative Efficacy of Different AI Systems for Polyp Detection by Size During Colonoscopy: Systematic Review and Network Meta-Analysis},
journal = {Journal of Medical Internet Research},
year = {2026},
volume = {28},
pages = {e95841},
doi = {10.2196/95841}
}
EUVIMED