Digital Markers for Passive Remote Monitoring of Bipolar Disorder: Systematic Review
JMIR Mental Health · 13.08.2026 · 13 · e94819-e94819
DOI: 10.2196/94819 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift JMIR Mental Health, online erschienen am 13.08.2026. Verfasst von Thomas P Kutcher und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical & Computer Engineering, Rice University, Houston, TX, United States. Hauptthemen laut MEDLINE: Bipolar Disorder, Wearable Electronic Devices. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 91 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NLM NIH HHS, NINDS NIH HHS.
Abstract (Originalsprache)
Background
Bipolar disorder (BD) features episodic shifts among mania, hypomania, depression, mixed states, and euthymia. Timely detection of mood transitions is difficult due to infrequent clinical touchpoints. Digital health technologies, including wearables and smartphones, offer a unique opportunity to passively and continuously monitor behavior and physiology that could reflect underlying mood dynamics in real-world settings.
Objective
This study aimed to systematically review passively collected digital markers for BD mood states, characterize devices/modalities and analytic approaches, appraise risk of bias, and identify design gaps and priorities for clinical translation.
Methods
Following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines, we searched MEDLINE, PsycINFO, Scopus, IEEE Xplore, and ACM Digital Library (February 16, 2026). We included peer-reviewed studies of adults with bipolar I disorder or bipolar II disorder (BDI or BDII) that measured passively collected markers and related them to depressive, manic, hypomanic, mixed, or euthymic states. Studies that relied exclusively on active measures (eg, lab tests and ecological momentary assessment) were excluded. Two independent reviewers screened studies, extracted study characteristics and results, conducted narrative synthesis, and assessed risk of bias.
Results
Of 23,727 records, 57 studies met criteria. Most enrolled ≤50 participants (n=34, 60%) and monitored ≤365 days (n=46, 81%); 11 out of 57 studies (19%) collected data only in the clinic. Eight digital marker domains emerged: physical activity, heart rate (HR), electrodermal activity (EDA), geolocation, smartphone use, light exposure, sleep, and speech. Consistent patterns linked depression to reduced mobility and social interaction, later/variable sleep, and lower daytime light; mania and hypomania were associated with higher and more variable activity, shorter/advanced sleep, and increased communication. Circadian features derived from sleep/activity repeatedly aided prediction. EDA tended to be lower in depression; HR variability findings were mixed across settings and methods. Keyboard and speech features (eg, timing and prosody) showed associations and performed well in classification models. Twenty-one studies used machine learning; several reported strong performance for episode prediction/classification. However, external validation was usually absent, samples were small, monitoring windows were often short relative to episode timescales, clinical labels were infrequent/misaligned, and missingness was rarely modeled despite likely informativeness.
Conclusions
Passive digital markers for BD show promise, with the most robust signals aligning with DSM-5 ( Diagnostic and Statistical Manual of Mental Disorders [Fifth Edition]) diagnostic features (sleep-wake patterns, activity, socialization, geolocation, and speech). To move from promise to practice, future studies should adopt longer within-subject monitoring, align label cadence with sensing granularity, standardize features/reporting, preregister analyses, externally validate models, minimize data collection to protect privacy, and expand physiological measurement beyond HR and EDA. These steps are essential to develop reliable, actionable tools for earlier detection and management of BD mood episodes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical & Computer Engineering, Rice University, Houston, TX, United States.
- Center for Medical Ethics and Health Policy, Baylor College of Medicine, Houston, TX, United States.
- Menninger Department of Psychiatry and Behavioral Sciences, Baylor College of Medicine, Houston, TX, United States.
- Department of Neurological Surgery, University of Washington, Seattle, WA, United States.
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston, TX, 77030, United States, 1 713 798 4696, 1 713 798 3739.
- Neuroengineering Initiative, Rice University, Houston, TX, United States.
Förderung
- NLM NIH HHS
- NINDS NIH HHS
Zitieren
APA
Kutcher, T. P., Chakraborty, I., Kostick-Quenet, K., Sano, A., Moukaddam, N., Herron, J. A., Goodman, W. K., Sheth, S. A., Sabharwal, A., & Provenza, N. R. (2026). Digital Markers for Passive Remote Monitoring of Bipolar Disorder: Systematic Review. JMIR Mental Health, 13, e94819-e94819. https://doi.org/10.2196/94819
Vancouver
Kutcher TP, Chakraborty I, Kostick-Quenet K, Sano A, Moukaddam N, Herron JA, et al. Digital Markers for Passive Remote Monitoring of Bipolar Disorder: Systematic Review. JMIR Mental Health. 2026;13:e94819-e94819. doi:10.2196/94819
BibTeX
@article{Kutcher2026,
author = {Kutcher, Thomas P and Chakraborty, Isha and Kostick-Quenet, Kristin and Sano, Akane and Moukaddam, Nidal and Herron, Jeffrey A and Goodman, Wayne K and Sheth, Sameer A and Sabharwal, Ashutosh and Provenza, Nicole R},
title = {Digital Markers for Passive Remote Monitoring of Bipolar Disorder: Systematic Review},
journal = {JMIR Mental Health},
year = {2026},
volume = {13},
pages = {e94819--e94819},
doi = {10.2196/94819}
}
EUVIMED