EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitScoping ReviewOpen Access

Quantitative Electroencephalography in Hemodialysis: Scoping Review and Translational Framework

Meng-Hsun Tsai, Cheng-Hsiung Chan

JMIR Biomedical Engineering · 31.07.2026 · 11 · e94560-e94560

DOI: 10.2196/94560 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift JMIR Biomedical Engineering, online erschienen am 31.07.2026. Verfasst von Meng-Hsun Tsai und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, National Yunlin University of Science and Technology, No. 123, Section 3, University Road, Douliu, Yunlin, 6400…. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cognitive impairment and cerebral dysfunction are common among patients with end-stage kidney disease undergoing maintenance hemodialysis. Repeated intradialytic hemodynamic stress, including reductions in cerebral blood flow and episodes of intradialytic hypotension, has been associated with adverse neurological outcomes. Quantitative electroencephalography (qEEG) offers a noninvasive approach for continuous assessment of cerebral activity; however, its potential role in dialysis monitoring remains unclear because of methodological heterogeneity and implementation challenges.

Objective

This scoping review aimed to synthesize current evidence regarding qEEG alterations across the hemodialysis cycle and to evaluate the technical requirements for translating qEEG-derived features into future dialysis-related cerebral monitoring systems.

Methods

A structured literature search was conducted in PubMed/MEDLINE, Embase, and IEEE Xplore for studies published between January 2005 and February 2026. After removal of duplicates, 554 records were screened, and 70 full-text articles were assessed for eligibility. Sixty-two studies met the inclusion criteria and were included in the qualitative synthesis. Evidence was organized according to the 3 temporal domains of the hemodialysis cycle: predialysis baseline, intradialytic exposure, and postdialysis recovery. In addition to clinical findings, engineering-related evidence concerning electroencephalography hardware, electrode systems, signal processing pipelines, artifact mitigation, multimodal synchronization, edge computing, and digital biomarker validation was reviewed.

Results

Patients receiving maintenance hemodialysis consistently demonstrated baseline spectral slowing characterized by increased delta and theta activity, and reduced alpha power. During dialysis, multimodal imaging studies reported cerebral blood flow reductions of approximately 10% to 15%, accompanied by dynamic qEEG changes, including alterations in the alpha-delta ratio and slow wave activity. Connectivity and complexity measures provided complementary information regarding network-level and recovery-related responses but showed substantial variability across acquisition conditions and analytical pipelines. Major implementation challenges included electrical interference, motion artifacts, electrode instability, asynchronous physiological data streams, and limited standardization of preprocessing methods. Comparative analysis indicated that acquisition quality, artifact rejection performance, synchronization accuracy, and individualized baseline modeling are critical determinants of translational feasibility.

Conclusions

Current evidence indicates that qEEG-derived measures have been reported in association with both chronic and intradialytic neurophysiological changes in patients undergoing hemodialysis. However, available evidence remains heterogeneous and insufficient to support routine clinical deployment. Future implementation will require standardized acquisition protocols, robust artifact mitigation, synchronized multimodal monitoring, and prospective validation studies. At present, qEEG-derived features should be regarded as candidate digital biomarkers and components of a proposed translational monitoring framework rather than clinically validated monitoring tools.

Schlagwörter

Stichwörter der Autor:innen

cerebral blood flowcognitive impairmentdigital biomarkerhemodialysisintradialytic monitoringmultimodal synchronizationquantitative electroencephalographysignal processing

Autor:innen und Institutionen

  • Department of Mechanical Engineering, National Yunlin University of Science and Technology, No. 123, Section 3, University Road, Douliu, Yunlin, 64002, Taiwan, 886 5-534-2601 ext 4102, 886 5-532-1719.

Zitieren

APA

Tsai, M. H., & Chan, C. H. (2026). Quantitative Electroencephalography in Hemodialysis: Scoping Review and Translational Framework. JMIR Biomedical Engineering, 11, e94560-e94560. https://doi.org/10.2196/94560

Vancouver

Tsai MH, Chan CH. Quantitative Electroencephalography in Hemodialysis: Scoping Review and Translational Framework. JMIR Biomedical Engineering. 2026;11:e94560-e94560. doi:10.2196/94560

BibTeX
@article{Tsai2026,
  author = {Tsai, Meng-Hsun and Chan, Cheng-Hsiung},
  title = {Quantitative Electroencephalography in Hemodialysis: Scoping Review and Translational Framework},
  journal = {JMIR Biomedical Engineering},
  year = {2026},
  volume = {11},
  pages = {e94560--e94560},
  doi = {10.2196/94560}
}
Kostenlos starten →