Timed Up-and-Go Test Using Instrumented Insoles to Monitor Tibial or Malleolar Fracture Healing in Patients With Healing Fractures or Nonunion: Longitudinal and Cross-Sectional Exploratory Study
JMIR mHealth and uHealth · 21.09.2026 · 14 · e92493-e92493
DOI: 10.2196/92493 ↗Kurz gefasst
Querschnittstudie in der Zeitschrift JMIR mHealth and uHealth, online erschienen am 21.09.2026. Verfasst von Elke Warmerdam und 2 weiteren Autor:innen. Beteiligte Einrichtung: Innovative Implant Development (Fracture Healing), Departments and Institutes of Surgery, Saarland University, Kirrberger Str. 100, Building 57, Homb…. Hauptthemen laut MEDLINE: Fracture Healing, Ankle Fractures, Foot Orthoses, Tibial Fractures. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
The timed up-and-go (TUG) test is a mobility-related functional task commonly performed in clinical practice for a variety of clinical applications. By instrumenting the TUG test with sensors, creating an instrumented TUG (iTUG), additional parameters can be extracted, which may add clinical value. Instrumented insoles are among the most promising wearable devices that are currently being explored for clinical purposes.
Objective
The study aims to assess additional parameters obtained by instrumenting the TUG test with pressure-sensing insoles for monitoring fracture healing and to analyze whether these parameters reveal differences between patients with and without union of tibial or malleolar fractures.
Methods
Patients with tibial or malleolar fractures and matched controls were enrolled. Patients’ TUG test data were collected as follows: (1) longitudinally—at 6 weeks, 3 months, and 6 months after surgery—and (2) cross-sectionally—at 6 months after surgery when patients were referred for nonunion treatment. All participants performed the TUG test using instrumented insoles. TUG tests were video-recorded and analyzed in terms of the time taken to complete each part of the TUG test (conventional TUG). The insole data-derived outcome measures were maximal force during sit-to-stand and stand-to-sit movements, stance time and stride time during walking, and asymmetry of the previously mentioned parameters (iTUG).
Results
Twenty-seven patients with fracture, a similar number of healthy adults, and 9 patients with fracture nonunion were assessed. All TUG parameters improved throughout the healing process (all P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Innovative Implant Development (Fracture Healing), Departments and Institutes of Surgery, Saarland University, Kirrberger Str. 100, Building 57, Homburg, Saarland, 66421, Germany, +49 68411631570.
Zitieren
APA
Warmerdam, E., Burger, L. M., & Ganse, B. (2026). Timed Up-and-Go Test Using Instrumented Insoles to Monitor Tibial or Malleolar Fracture Healing in Patients With Healing Fractures or Nonunion: Longitudinal and Cross-Sectional Exploratory Study. JMIR mHealth and uHealth, 14, e92493-e92493. https://doi.org/10.2196/92493
Vancouver
Warmerdam E, Burger LM, Ganse B. Timed Up-and-Go Test Using Instrumented Insoles to Monitor Tibial or Malleolar Fracture Healing in Patients With Healing Fractures or Nonunion: Longitudinal and Cross-Sectional Exploratory Study. JMIR mHealth and uHealth. 2026;14:e92493-e92493. doi:10.2196/92493
BibTeX
@article{Warmerdam2026,
author = {Warmerdam, Elke and Burger, Lea-Marie and Ganse, Bergita},
title = {Timed Up-and-Go Test Using Instrumented Insoles to Monitor Tibial or Malleolar Fracture Healing in Patients With Healing Fractures or Nonunion: Longitudinal and Cross-Sectional Exploratory Study},
journal = {JMIR mHealth and uHealth},
year = {2026},
volume = {14},
pages = {e92493--e92493},
doi = {10.2196/92493}
}
EUVIMED