EUVIMEDEUVIMED entdecken
Mixed-Methods-StudieOpen Access

Toward Patient-Centric Digital Monitoring of Obstructive Sleep Apnea: Mixed Methods Study

James Kenneth Timmis iD, Kerstin Alexandra Schorr iD, Rana Yüksel iD, Tim van den Broek iD, Sebastiaan Overeem iD, Dagmar Josine Smid iD, Willem Johan van den Brink iD, Nina Leonie Haring iD

Journal of Medical Internet Research · 2026

DOI: 10.2196/82460 ↗

Kurz gefasst

Mixed-Methods-Studie in der Zeitschrift Journal of Medical Internet Research, 2026. Verfasst von James Kenneth Timmis und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Political Science, University of Freiburg, Freiburg, Baden-Wurttemberg, Germany. Hauptthemen laut MEDLINE: Sleep Apnea, Obstructive. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Obstructive sleep apnea (OSA) is a sleep disorder characterized by repeated breathing disruptions during sleep. Remote patient monitoring (RPM) of OSA is important, yet contemporary methods are limited. Sensor-based digital health technologies (sDHTs) promise a step advance in OSA RPM, but must provide meaningful, actionable, and usable outputs for patients. While the centrality of considering patient views in sDHT development is widely acknowledged, patient perspectives and priorities are rarely assessed.

Objective

This study aimed to identify patient-prioritized health aspects and preferences for digital measures and RPM to enhance OSA care quality and patient experience, guided by the digital measures that matter framework.

Methods

We used a mixed methods design combining quantitative and qualitative approaches. Individuals with a formal OSA diagnosis and persistent sleep problems (n=223) completed a survey in which they ranked items related to treatment burdens and health priorities, and responded to open-ended questions about restoring previous quality-of-life elements and desired health goals. To gain deeper qualitative insights, we conducted semistructured interviews with patients with OSA, patient advocates, and health care professionals (n=11), focusing on follow-up care, attitudes toward sDHTs and RPM, and preferences for future OSA-related sDHTs and metrics. Quantitative data were analyzed using bootstrap-aggregated Borda counts (broad support) and Plackett-Luce modeling (intense prioritization), while qualitative data from surveys and interviews were analyzed thematically.

Results

Key meaningful aspects of health included the improvement of subjective sleep quality (top-ranked burden; health goal for 46.5%, 93/200 of participants), an increase in daytime energy (quality-of-life aspect to restore for 35.6%, 72/202 and health goal for 25.5%, 51/200 of participants), and physical activity (quality-of-life aspect to restore for 24.7%, 50/202 and health goal for 16.5%, 33/200 of participants). Sleep characteristics and daytime energy were priority targets for digital measure development. Smartwatches, sleep mats, and smart rings were preferred modalities for integration into RPM. Participants’ priorities for enhancing monitoring included (1) expanding metrics beyond the Apnea-Hypopnea Index (AHI; 36.6%, 52/142), (2) improving measurement accuracy (20.4%, 29/142), and (3) ensuring outputs are meaningful, understandable (18.3%, 26/142), and actionable (9.2%, 13/142). Patients also reported difficulty interpreting RPM data to determine if and when follow-up care is needed and what type of care is appropriate.

Conclusions

RPM solutions for OSA should expand beyond AHI, ensure accuracy and interpretability, and provide actionable insights to support comprehensive patient-centric management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Sleep Apnea, ObstructiveHumansMaleFemaleDigital HealthMiddle AgedRemote Patient MonitoringAdultMonitoring, PhysiologicAgedSurveys and QuestionnairesQuality of Life

Stichwörter der Autor:innen

digital biomarkersdigital outcome measuresobstructive sleep apneapatient-centric carepatient-reported outcomesremote patient monitoringwearable sensors

Autor:innen und Institutionen

  • Department of Political Science, University of Freiburg, Freiburg, Baden-Wurttemberg, Germany.
  • Athena Institute for Research on Innovation and Communication in Health and Life Sciences, Vrije Universiteit Amsterdam, Amsterdam, North Holland, The Netherlands.
  • Research Group Microbiology and Systems Biology, Netherlands Organization for Applied Scientific Research (TNO), Leiden, The Netherlands.
  • Sleep Medicine Center Kempenhaeghe, Heeze, The Netherlands.
  • Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
  • Research Group Human Performance, Netherlands Organisation for Applied Scientific Research (TNO), Soesterberg, The Netherlands.

ORCID-Profile: James Kenneth Timmis, Kerstin Alexandra Schorr, Rana Yüksel, Tim van den Broek, Sebastiaan Overeem, Dagmar Josine Smid, Willem Johan van den Brink, Nina Leonie Haring

Zitieren

APA

Timmis, J. K., Schorr, K. A., Yüksel, R., van den Broek, T., Overeem, S., Smid, D. J., van den Brink, W. J., & Haring, N. L. (2026). Toward Patient-Centric Digital Monitoring of Obstructive Sleep Apnea: Mixed Methods Study. Journal of Medical Internet Research. https://doi.org/10.2196/82460

Vancouver

Timmis JK, Schorr KA, Yüksel R, van den Broek T, Overeem S, Smid DJ, et al. Toward Patient-Centric Digital Monitoring of Obstructive Sleep Apnea: Mixed Methods Study. Journal of Medical Internet Research. 2026. doi:10.2196/82460

BibTeX
@article{Timmis2026,
  author = {Timmis, James Kenneth and Schorr, Kerstin Alexandra and Yüksel, Rana and van den Broek, Tim and Overeem, Sebastiaan and Smid, Dagmar Josine and van den Brink, Willem Johan and Haring, Nina Leonie},
  title = {Toward Patient-Centric Digital Monitoring of Obstructive Sleep Apnea: Mixed Methods Study},
  journal = {Journal of Medical Internet Research},
  year = {2026},
  doi = {10.2196/82460}
}
Kostenlos starten →