EUVIMEDEUVIMED entdecken
Open Access

Effect of a Spinal Orthosis With Leaf Spring and Programmable Local Vibration on Kyphosis Angle and Trunk Muscle Strength in Hyperkyphosis: Development and Feasibility Study

Fatemeh Keshavarzi, Mokhtar Arazpour, Saeed Behzadipour

JMIR Biomedical Engineering · 25.06.2026 · 11 · e82013-e82013

DOI: 10.2196/82013 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JMIR Biomedical Engineering, online erschienen am 25.06.2026. Verfasst von Fatemeh Keshavarzi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Orthotics and Prosthetics Department, University of Social Welfare and Rehabilitation Sciences, Kodakyar St, Daneshjo Blvd, Evin, Tehran, 1985713871,…. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The application of spinal orthoses and local vibration in the treatment of hyperkyphosis is a developing concept. Further research is needed to determine the impact of leaf springs and local vibration techniques on the neuromusculoskeletal system.

Objective

This study aimed to evaluate the effect of the simultaneous application of a leaf spring and a programmed local vibration system in a spinal orthosis on thoracic kyphosis angle (TKA) and the function of trunk flexor and extensor muscles.

Methods

We used a soft thoracolumbar orthosis as a base for 2 parallel leaf spring bars made from AISI (American Iron and Steel Institute) 1075 steel (45 cm × 2 cm × 2 mm each). We added 4 solenoid actuators (60 g each) housed in 2 units positioned 12 cm apart, generating 20 N vertical force at 8 Hz frequency with 10 mm free displacement. A programmable Arduino microcontroller delivered 10-second vibration bursts followed by 5-minute rest intervals, repeated for 12 cycles per session, applied every other day. One participant with hyperkyphosis (baseline TKA=47.24°) used this device for 4 weeks. Outcomes included TKA (measured by photogrammetry) and trunk muscle function (assessed under isometric, isotonic, and isokinetic conditions). Feasibility outcomes included adherence, wear time, and adverse events.

Results

Bench testing confirmed an 8 Hz vibration frequency, a 10 mm free displacement, and an on-body contact pressure of 9.5 N/cm² (95 kPa). In the short-term assessment (N=10), mean acceptability scores were 7.95 (SD 0.83) for appearance and 7.6 (SD 0.07) for comfort, and no skin-related adverse events occurred. In the 4-week single-participant pilot (N=1), adherence was 100% (12/12 sessions completed), mean daily wear time was 1.4 (SD 0.3) hours, and no adverse events were reported. TKA decreased from 47.24° to 45.81° (change: −1.43°), which did not exceed the minimal detectable change (4.62°). Pre-post changes in muscle function outcomes are reported descriptively.

Conclusions

A semirigid thoracolumbar orthosis with integrated programmable vibration (8 Hz, 20 N free force) is technically feasible, showing reliable bench performance. Short-term assessment in 10 participants indicated acceptable comfort and appearance with no immediate safety concerns. The 4-week single-participant pilot demonstrated 100% adherence and no adverse events. The observed 1.43° kyphosis reduction was not clinically meaningful (below minimal detectable change). Larger controlled studies are needed to determine whether this device improves muscle function or spinal alignment.

Schlagwörter

Stichwörter der Autor:innen

kyphosismuscle strengthorthotic devicesspinevibration

Autor:innen und Institutionen

  • Orthotics and Prosthetics Department, University of Social Welfare and Rehabilitation Sciences, Kodakyar St, Daneshjo Blvd, Evin, Tehran, 1985713871, Iran, 98 021-2218-0083, 98 021-2218-0109.
  • Djawad Movafaghian Research Center in Rehab Technologies, Sharif University of Technology, Tehran, Iran.

Zitieren

APA

Keshavarzi, F., Arazpour, M., & Behzadipour, S. (2026). Effect of a Spinal Orthosis With Leaf Spring and Programmable Local Vibration on Kyphosis Angle and Trunk Muscle Strength in Hyperkyphosis: Development and Feasibility Study. JMIR Biomedical Engineering, 11, e82013-e82013. https://doi.org/10.2196/82013

Vancouver

Keshavarzi F, Arazpour M, Behzadipour S. Effect of a Spinal Orthosis With Leaf Spring and Programmable Local Vibration on Kyphosis Angle and Trunk Muscle Strength in Hyperkyphosis: Development and Feasibility Study. JMIR Biomedical Engineering. 2026;11:e82013-e82013. doi:10.2196/82013

BibTeX
@article{Keshavarzi2026,
  author = {Keshavarzi, Fatemeh and Arazpour, Mokhtar and Behzadipour, Saeed},
  title = {Effect of a Spinal Orthosis With Leaf Spring and Programmable Local Vibration on Kyphosis Angle and Trunk Muscle Strength in Hyperkyphosis: Development and Feasibility Study},
  journal = {JMIR Biomedical Engineering},
  year = {2026},
  volume = {11},
  pages = {e82013--e82013},
  doi = {10.2196/82013}
}
Kostenlos starten →