EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access

Photoplethysmography-Based Machine Learning Approaches for Atrial Fibrillation Burden: Algorithm Development and Validation

Hong Wang, Binbin Liu, Hui Zhang, Zheqi Zhang, Zhigeng Jin, Hao Wang, Yu-Tao Guo

JMIR Cardio · 10.11.2025 · 9 · e78075-e78075

DOI: 10.2196/78075 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift JMIR Cardio, online erschienen am 10.11.2025. Verfasst von Hong Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pulmonary Vessel and Thrombotic Disease, Sixth Medical Center, Chinese PLA General Hospital, 6 Fucheng Road, Haidian District, Beijing,…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Photoplethysmography, Machine Learning, Algorithms. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Atrial fibrillation (AF) burden is associated with cardiovascular events such as stroke and heart failure. Recent advancements in photoplethysmography (PPG) technology have provided new insights into noninvasive and convenient AF burden detection.

Objective

This study aimed to establish an AF burden model based on smartwatch-monitored PPG technology to track the progression of AF.

Methods

This prospective pilot study (January 2024 to January 2025) at the Chinese PLA General Hospital enrolled patients with paroxysmal AF. Participants underwent simultaneous rhythm monitoring using smartwatch PPG and 24-hour Holter electrocardiogram monitoring (the gold standard). Five PPG-derived AF burden metrics were defined: (1) ratio of AF episode duration to total monitoring time (M1), (2) ratio of AF episode frequency to total measurements (M2), (3) AF episode density (M3), (4) AF episode variability (M4), and (5) proportion of rapid ventricular rate in AF episodes (>120 beats per minute; M5). Smartwatch PPG signals were collected once per minute. Sensitivity, specificity, accuracy, precision, and F 1 score were used to evaluate the PPG algorithm’s AF detection capability through comparison with the gold standard (24-hour Holter monitoring). The mean absolute error (MAE) and Spearman rank correlation coefficient ( r s ) were used to assess the correlation between the PPG-based AF burden metrics and the gold standard.

Results

A total of 145 participants with paroxysmal AF (n=96, 66.2% male; mean age 63.28, SD 14.23 years) were included. Compared to the gold standard, the PPG-based AF burden model demonstrated a sensitivity of 91.5% (95% CI 87.9%-95.1%), specificity of 97.2% (95% CI 95.9%-98.5%), precision of 92.9% (95% CI 88.6%-97.3%), accuracy of 93.3% (95% CI 88.2%-98.5%), and F 1 score of 90.5% (95% CI 86.3%-94.7%). The AF burden model exhibited strong discriminatory power in the test cohort (area under the curve=89.5%, 95% CI 89.4%‐89.7%). For M1, the MAE for the model of AF episode duration as a proportion of total monitoring time was 0.0400 ( P =.008), with a correlation coefficient ( r s ) of 0.8788 ( P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationPhotoplethysmographyMachine LearningAlgorithmsHumansMaleFemaleProspective StudiesMiddle AgedAgedPilot ProjectsElectrocardiography, Ambulatory

Stichwörter der Autor:innen

arrhythmiaatrial fibrillationatrial fibrillation burdenphotoplethysmographywearable devices

Autor:innen und Institutionen

  • Department of Pulmonary Vessel and Thrombotic Disease, Sixth Medical Center, Chinese PLA General Hospital, 6 Fucheng Road, Haidian District, Beijing, 100048, China, +86-10-66957703.
  • Graduate School of PLA General Hospital, Beijing, China.
  • Department of Cardiology, Second Medical Centre, National Clinical Research Centre for Geriatric Diseases, Chinese PLA General Hospital, Beijing, China.

Zitieren

APA

Wang, H., Liu, B., Zhang, H., Zhang, Z., Jin, Z., Wang, H., & Guo, Y. T. (2025). Photoplethysmography-Based Machine Learning Approaches for Atrial Fibrillation Burden: Algorithm Development and Validation. JMIR Cardio, 9, e78075-e78075. https://doi.org/10.2196/78075

Vancouver

Wang H, Liu B, Zhang H, Zhang Z, Jin Z, Wang H, et al. Photoplethysmography-Based Machine Learning Approaches for Atrial Fibrillation Burden: Algorithm Development and Validation. JMIR Cardio. 2025;9:e78075-e78075. doi:10.2196/78075

BibTeX
@article{Wang2025,
  author = {Wang, Hong and Liu, Binbin and Zhang, Hui and Zhang, Zheqi and Jin, Zhigeng and Wang, Hao and Guo, Yu-Tao},
  title = {Photoplethysmography-Based Machine Learning Approaches for Atrial Fibrillation Burden: Algorithm Development and Validation},
  journal = {JMIR Cardio},
  year = {2025},
  volume = {9},
  pages = {e78075--e78075},
  doi = {10.2196/78075}
}
Kostenlos starten →